GASMAX II Gas Monitor - Detector ( 0 -1.0 % HYDROGEN)

GMII: GASMAX II Gas MonitorSingle / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations
Chanel 1
- 2: Sensor Head (Local sensor head with splash guard)
- 14: Senor Type (Smart)
- 1: Target Gas Range (0 – 1 % H2)
Chanel 2
- 0: Sensor Head (No sensor head)
- 00: Senor Type (No sensor)
- 0: Target Gas Range (None)
Output- 0: standard 4 -20 ma output (3-wires)
- 0: standard temperature range
GASMAX II Gas Monitor Single / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations
- Power Input: 10-30VDC at < 4 watts with relay board. Additional power required for Extended Temp & GDS-IR option.
- Display: Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph
- Electrochemical Sensor Input: Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors or 4-20mA current source
- Bridge Type Sensor Input: Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead or 4-20mA current source
- Standard Output: Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
- Optional Outputs: Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC; Single or dual MODBUS slave ports; 3x program-mable alarm relays with 5A capability
- Temp: Electronics -40°C to +60°C; See Echem Sensor Manual for sensor limits
- Housing : Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
- Dimensions: Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
- Approvals: CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP installations
- Warranty: 2 years on electronics and one year on sensors
S/ 7,618.80 7618.8 PEN
Detector de Ozono (O3: rango 0 a 1 ppm)
 GMII:    GASMAX II , Gas Monitor for toxics, combustibles and VOCs
3:           channel 1: Local sensor head for reactive gases(non XP)
21:         sensor type, Ozone
1:           Range 0 to 1.0 PPM
0:            channel 2:  No sensor head
00:         sensor type: No sensor head
0:           range: none
0:           output: standard 4-20 ma
0:           standard temperature range

GASMAX II Gas MonitorSingle / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations
Power Input: 10-30VDC at < 4 watts with relay board. Additional power required for Extended Temp & GDS-IR option.
Display: Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph
Electrochemical Sensor Input: Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors or 4-20mA current source
Bridge Type Sensor Input: Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead or 4-20mA current source
Standard Output: Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Outputs: Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC; Single or dual MODBUS slave ports; 3x program-mable alarm relays with 5A capability
Temp: Electronics -40°C to +60°C; See Echem Sensor Manual for sensor limits
Housing : Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
Dimensions: Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals: CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP installations
Warranty: 2 years on electronics and one year on sensors
S/ 8,235.56 8235.56 PEN
Accesorios Proyecto PRAXAIR
Accesorios
05 SELLOS ANTIEXPLOSIVOS 3/4
15 TUBERIA FLEXIBLE CON MALLA METALICA ANTIEXPLOSIVA DE 3/4 (05 PARA SENSORES,08 PARA LUMINARIAS Y 02 PARA TABLERO)
13 UNION ANTIEXPLOSIVA DE 3/4
01 CAJA DE PASO
ACCESORIOS CONSUMIBLES
S/ 8,380.68 8380.68 PEN
Transmisor detector de gas Sensepoint XCD Honeywell
Modelo: SPXCDULNG2
• Honeywell Sensepoint XCD Gas Detector
RTD Transmitter
• Sensor Type: Hydrogen; 0-1,000ppm
• Enclosure Material: Epoxy painted aluminum alloy
• Communication: None
• Range Increments   N/A
• Class I, Division 2   Yes
• Lower Alarm 200ppm
• Lower Alarm Type   Rising
• Higher Alarm 400ppm
• Higher Alarm Type  Rising
• Lowest Alarm Level 100ppmModelo: 2106B1416
Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector,
H2 0-1000 ppm
Toxic Sensor M2
S/ 7,444.66 7444.66 PEN
Toxic Sensor H2 - HONEYWELL
Modelo: 2106B1416Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector,
H2 0-1000 ppm
Toxic Sensor M20
S/ 4,252.02 4252.02 PEN
Transmisor detector de gas Sensepoint XCD Honeywell
Modelo: SPXCDULNG2
• Honeywell Sensepoint XCD Gas Detector
• Sensor Type: Hydrogen; 0-1,000ppm
• Enclosure Material: Epoxy painted aluminum alloy
• Conduit Entry: 3/4 inch NPT
• Communication: None
S/ 4,894.17 4894.17 PEN
CARBON DIOXIDE TRASMITTER
CARBON DIOXIDE TRASMITTER
Brand: DWYER
Model: CDT-2D40
[CDT] Carbon dioxide/temperature transmitter
[2] Range: 0 to 2000 PPM CO2 range
[D] Configuration: Duct mount
[4] CO2: 4-20 mA / 0 to (5 or 10) VDC
[0] Temperature Output: None
S/ 0.00 0.0 PEN
Detector Portable Multi-gas (E6000-O2-CO-CO2-NO2-CH4-SO2)
Detector Portable Multi-gas
Model: E6000-O2-CO-CO2-NO2-CH4-SO2
Modulo de Sensor Inteligente Intercambiable
Intrinsecamente seguro
Alarma visual, audible y vibrativa.
Niveles de alarma y valor de calibración ajustables.
Niveles STEL y TWA
Reloj en tiempo real
Funciones de auto diagnostico y auto corrección.
S/ 6,711.80 6711.8 PEN
Detector Portable Multi-gas (E6000-O2-CO-CO2-NO2-CH4–H2S)
Detector Portable Multi-gas
Model: E6000-O2-CO-CO2-NO2-CH4–H2S
Modulo de Sensor Inteligente Intercambiable
Intrinsecamente seguro
Alarma visual, audible y vibrativa.
Niveles de alarma y valor de calibración ajustables.
Niveles STEL y TWA
Reloj en tiempo real
Funciones de auto diagnostico y auto corrección.
S/ 6,711.80 6711.8 PEN