FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter,DN50 DN700
Modelo: INT-100H + HM + HS
• FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter
• Brand (INTRIAL), Made in Taiwan for INTRIAL
• Measuring Accuracy Flowmeter/Calorimeter: Better than 1% ; Water meter: Better than 2%; Heat Meter: EN1434 Standard
• Repeatability Better than 0.2% or 0.5%
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
• Velocity ±0.03~±105ft/s(±0.01~±32m/s),bi-ditectional
• Pipe Material Steel, stainless steel, cast iron, copper, PVC, aluminum, glass reinforced plastics or other compact pipe and lined pipe allowed
• Liquid Temp 32 F~320 F (0 C~160 C)
• Output Interface OCT, RS232
• Battery and Power 3AAA Ni-H built-in batteries, when fully recharged, it will last over 12 hours of operation.
• 90V-230VAC for the charger
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
TRANSDUCTORES QUE INCLUYE:
HM
• Medium size trasducer(magnetic with mounting rack)
• Dim 11”*1.6”*1.6”(180*40*40mm3) for each
• For pipe size 2”~28”(DN50~DN700mm)
HS
• Handheld small size trasducer(magnetic with mounting rack and handle)
• Dim 7.9”*1”*1”(200*2.5*2.5mm3), handle length 3.9”(100mm)
• For pipe size1/2”~4”(DN15mm~100mm)
S/
5,535.35
5535.35
PEN
MEDIDOR DE CAUDAL ULTRASONIDO
MEDIDOR DE CAUDAL ULTRASONIDO
• Medición externa (Sin contacto con el líquido)
• Principio De Medición : Tiempo En Transito
• Marca: (INTRIAL)
• Alimentación : 220 VAC / 10…30 VDC . Seleccionable
• Sensores magnéticos , para montaje externo a la tubería.
• Sensores sin contacto con el fluido (*)
• Temperatura del Fluído : -40 á 100 ºC
• Indicación digital de flujo instantáneo
• Indicación digital de totalizador
• Salida analógica 4…20 mA
• Salida de pulsos para totalizador remoto
• Precisión : +/- 1 %
• Programación por teclado frontal
• Fluidos Preprogramados :
• Agua . Agua de Mar, Gasolina, Petróleo Diesel ,
• Petróleo Crudo, Kerosene , Alcohol, Aceite .
• (Para otros fluidos se debe conocer la velocidad del sonido)
• Analizador de flujo para montaje en pared
• Incluye abrazaderas para montaje de sensores
• Incluye manual de operaciones en inglés
• Incluye un envase de silicona
//////Incluye: Sensor M2 - Para Tubería De 2” Hasta 28” Diámetro/////
S/
7,392.85
7392.85
PEN
TRANSMISOR DE FLUJO ULTRASONICO, LCD de 4 caracteres., 1 mm (0.04")., 0.25 a 5 m
Transmisor de flujo ultrasonico
Marca: Dwyer
Modelo: ULF
Servicio: Líquidos compatibles.
Materiales mojados: Sensor: polipropileno; Ventana acústica: ECTFE
Rangos: ULF-X1-XXX: 0.25 a 5 m (0.82 a 16.4 pies). ULF-X2-XXX: 10.6 a 15 m (96 a 49.2 pies).
Exactitud: 0.25% del rango máximo (a 20°C [68°F]).
Resolución: 1 mm (0.04").
Zona ciega: ULF-X1-XXX: 0.25 m (0.8 pies); ULF-X2-XXX: 0.6 m (1.96 pies).
Ángulo de haz: 5° a 3 db punto.
Límites de temperatura: -40 a 70 °C (-40 a 158 °F).
Compensación de temperatura: Automático.
Límites de presión: 0.9 a 2 bar (13.5 a 30 psi).
Requisito de alimentación eléctrica: 18 a 28 VCC.
Señal de Salida: 4 a 20 mA.
Resistencia de bucle: Max. 727Ω @ 28 VDC.
Conexiones eléctricas: Terminal de tornillo.
Conexión de conducto: NPT de 12.7 mm (1/2"), prensaestopas (opcional).
Conexión de proceso: NPT de 50.8 mm (2"), BSP de 12.7 mm (1/2") (opcional).
Gabinete armado estándar: Gabinete plástico: ABS y cuerpo con protección UV.
Clasificación del gabinete: NEMA 4 (IP 65).
Orientación de montaje: Vertical.
A prueba de fallas: Retardo de 3 minutos antes de transmitir una señal de error.
Memoria: No volátil.
Pantalla: LCD de 4 caracteres.
Unidades: pies, m (opcional).
Programación: 4 botones.
S/
4,610.32
4610.32
PEN
Ultrasonic Sensor
Ultrasonic Sensor UC500
Marca: Pepperl + Fuchs
Modelo: UC500-D1-3K-V7
Especificaciones Tecnicas:
- Especial para control del nivel de sobrellenado en recipientes
- Rango de tensión de trabajo amplio
**10 ... 253 V CC
**20 ... 253 V CA
- 03 Salidas relé
- Parametrización vía conmutadores DIP
- Compensación de temperatura
- El enchufe para el cable se incluye en el volumen de suministro
S/
2,548.49
2548.4900000000002
PEN
SENSOR CAUDAL, ULTRASONICO, 4-20mA
MEDIDOR DE CAUDAL ULTRASONICO,• Medición externa (Sin contacto con el líquido),• Principio De Medición : Tiempo En Transito,• Sensor M2 - Para Tubería De 2” Hasta 28” Diámetr,• Marca: (TER INSTRUMENTS),• Alimentación : 220 VAC / 10…30 VDC . Seleccionab,• Sensores magnéticos , para montaje externo a la ,• Sensores sin contacto con el fluido (*),• Temperatura del Fluído : -40 á 100 ºC,• Indicación digital de flujo instantáneo,• Indicación digital de totalizador,• Salida analógica 4…20 mA,• Salida de pulsos para totalizador remoto,• Precisión : +/- 1 %,• Programación por teclado frontal,• Fluidos Preprogramados :,• Agua . Agua de Mar, Gasolina, Petróleo Diesel ,,• Petróleo Crudo, Kerosene , Alcohol, Aceite .,• (Para otros fluidos se debe conocer la velocidad,• Analizador de flujo para montaje en pared,• Incluye abrazaderas para montaje de sensores,• Incluye manual de operaciones en inglés,• Incluye un envase de silicona
S/
0.00
0.0
PEN
Registrador de Flujo Ultrasonico Stringay 2.0
REGISTRADOR DE FLUJO ULTRASONICO STINGRAY 2.0
MARCA: GREYLINE (USA)
Grado de proteccion: IP67
Temperatura de funcionamiento: -20° a 60° C
Capacidad:130.000 puntos de datos
Salida/Comunicaciones: USB
Cable USB: 1 metro con blindaje
Software: Soporta el monitoreo en tiempo real
S/
18,054.90
18054.9
PEN
COMPACT ULTRASONIC FLOWMETERS, 0.33 to 32.8 ft/s (0.1 to 10 m/s)., 12 to 24 VDC or VAC.
COMPACT ULTRASONIC FLOWMETERS
Brand: Dwyer
Service: Clean water with < 3% by volume of particulate content.
Range: 0.33 to 32.8 ft/s (0.1 to 10 m/s).
Display: Backlit: 3.27" H x 0.74" W (83.1 mm x 18.8 mm), 2 line x 16 characters.
Accuracy: ±3% of flow reading for > 0.98 ft/s (> 0.3 m/s).
Power Requirements: 12 to 24 VDC or VAC.
Power Consumption: 7 W max.
Temperature Limits: Process: 32 to 185°F (0 to 85°C); Ambient: 32 to 122°F (0 to 50°C).
Outputs: Analog: 1 opto-isolated: 4 to 20 mA; Error current: 3.5 mA; Load resistance: 620 Ωmax; Pulse: 1 optoisolated MOSFET relay, 500 mA max, 166 pps max, 200 Hz max.
Enclosure Rating: IP54.
Enclosure Material: Plastic polycarbonate.
Repeatability: ±0.5% of measured value.
Electrical Connections: 16.4´ (5 m) cable.
Response Time: < 1 s.
Weight: 2.9 lb (1.315 kg).
Agency Approvals: CE.
Applicable Pipe Material: Steel, copper, or plastic.
Pipe Outside Diameter: 0.98 to 4.62" (24.89 to 117.35 mm).
Applicable Pipe Lining: None.
Pipe Wall Thickness: 0.02 to 0.39" (0.5 to 10 mm).
S/
9,283.79
9283.79
PEN
FLUJÓMETRO DOPPLER PORTÁTIL (DN25)
FLUJÓMETRO DOPPLER PORTÁTIL
- Non-invasive clampon sensor
- Hand held flowmeter
- Pipe sizes DN25
- Volumetric flow units of
measurement
- Metric and English units
- Easy to use
- Flow total and rate display
- Long battery life
- Data logger option
S/
13,708.35
13708.35
PEN
MEDIDOR PORTATIL DE CAUDAL ULTRASONIDO
MEDIDOR DE CAUDAL ULTRASONIDO
• Medición externa (Sin contacto con el líquido)
• Principio De Medición : Tiempo En Transito
• Marca: (INTRIAL)
• Alimentación : 220 VAC / 10…30 VDC . Seleccionable
• Sensores magnéticos , para montaje externo a la tubería.
• Sensores sin contacto con el fluido (*)
• Temperatura del Fluído : -40 á 100 ºC
• Indicación digital de flujo instantáneo
• Indicación digital de totalizador
• Salida analógica 4…20 mA
• Salida de pulsos para totalizador remoto
• Precisión : +/- 1 %
• Programación por teclado frontal
• Fluidos Preprogramados :
• Agua . Agua de Mar, Gasolina, Petróleo Diesel ,
• Petróleo Crudo, Kerosene , Alcohol, Aceite .
• (Para otros fluidos se debe conocer la velocidad del sonido)
• Analizador de flujo para montaje en pared
• Incluye abrazaderas para montaje de sensores
• Incluye manual de operaciones en inglés
• Incluye un envase de silicona
//////Incluye: ////////
• sensor Type High-Heat L2
• Large size transducer(magnetic with clamp-on fixture)
• Temperature 0~160°C
• For pipe size 11”~240”(DN300~6000mm)/////
S/
7,392.85
7392.85
PEN
FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter, DN300 DN6000
Modelo: INT-100H + L2
• FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter
• Brand (INTRIAL), Made in Taiwan for INTRIAL
• Measuring Accuracy Flowmeter/Calorimeter: Better than 1% ; Water meter: Better than 2%; Heat Meter: EN1434 Standard
• Repeatability Better than 0.2% or 0.5%
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
• Velocity ±0.03~±105ft/s(±0.01~±32m/s),bi-ditectional
• Pipe Material Steel, stainless steel, cast iron, copper, PVC, aluminum, glass reinforced plastics or other compact pipe and lined pipe allowed
• Liquid Temp 32 F~320 F (0 C~160 C)
• Output Interface OCT, RS232
• Battery and Power 3AAA Ni-H built-in batteries, when fully recharged, it will last over 12 hours of operation.
• 90V-230VAC for the charger
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
TRANSDUCTORES QUE INCLUYE:
L2
• Type High-Heat L2
• Large size transducer(magnetic with clamp-on fixture)
• Temperature 0~160°C
• For pipe size 11”~240”(DN300~6000mm)
HM
• Medium size trasducer (magnetic with mounting rack)
• Dim 11”*1.6”*1.6”(180*40*40mm3))
• For pipe size 2”~28”(DN50~DN700mm)
S/
5,535.35
5535.35
PEN
ULTRASONIC SENSOR CYLINDRICAL, Wiring technique: 4-wire, sensing range: 0.3…8 m
ULTRASONIC SENSOR CYLINDRICAL
Brand: SCHNEIDER ELECTRIC
Range of product: OsiSense XX
Sensor type: Ultrasonic sensor
Sensor design: Cylindrical M30
Detection system: Diffuse
[Sn] nominal sensing distance: 8 m adjustable with teach push-button
Material: Plastic
Type of output signal: Analogue
Wiring technique: 4-wire
Analog output function: 4...20 mA
[Us] rated supply voltage: 15...24 V DC with reverse polarity protection
Electrical connection Male connector M12 4 pins
[Sd] sensing range: 0.3…8 m
Beam angle 16 °
IP degree of protection: IP67 conforming to IEC 60529
S/
0.00
0.0
PEN
Juego de transductores ultrasónicos clamp-on
Juego de transductores ultrasónicos clamp-on<br />
Brand: FLEXIM<br />
Model: TRF-FSM-NF1TS-000<br />
[F]: para líquidos<br />
[S]: tipo de ondas transversales<br />
[M]: 1MHz<br />
Longitud del cable: 4m<br />
Diámetro nominal (recomendado): 100…1000 mm<br />
Diámetro nominal (ampliada): 50…1200 mm<br />
[N]: Temperatura de la superficie del tubo -40…130°C<br />
[F1TS]:<br />
[000]: sin cable de extensión
S/
19,414.59
19414.59
PEN
SENSOR ULTRASONICO
SENSOR ULTRASONICO<br />
Marca: PEPPERL & FUCH<br />
Rango de detección 30 ... 500 mm<br />
Rango de ajuste 50 ... 500 mm<br />
Zona ciega 0 ... 30 mm Tensión de trabajo UB 10<br />
30 V CC , rizado 10 %SS<br />
Corriente en vacío I0 ≤ 50 Ma<br />
Tipo de salida 2 salidas de conmutación pnp, <br />
N.A./N.C., parametrizable<br />
Medición de la corriente de trabajo Ie 2 x 100 mA <br />
a prueba de cortocircuito/sobrecarga<br />
Tipo de conexión Conector macho M12 x 1 , 5 polos<br />
Diámetro de la carcasa: 18 mm<br />
Grado de protección: IP67
S/
0.00
0.0
PEN
Sensor ultrasónico cilíndrico SCHNEIDER ELECTRIC
Sensor ultrasónico cilíndrico<br />
Marca: SCHNEIDER ELECTRIC<br />
Modelo: XX930A1A2M12<br />
Técnica de cableado de detector: 4 hilos<br />
Función de salida analógica: 4..0,20 mA<br />
[Us] tensión de alimentación asignada: 15...24 V<br />
Conector: Macho M12 4 patillas<br />
Grado de protección IP: IP67
S/
3,848.74
3848.7400000000002
PEN
SENSOR ULTRASONICO PEPPERL & FUCHS 30 ... 500 mm 10 ... 30 V CC 50 mA
SENSOR ULTRASONICO<br />
Marca: PEPPERL & FUCHS<br />
Modelo: UB500-18GM75-E23-V15<br />
Rango de detección, 30 ... 500 mm<br />
Rango de ajuste, 50 ... 500 mm<br />
Zona ciega, 0 ... 30 mm<br />
Estándar, 100 mm x 100 mm<br />
Frecuencia del transductor aprox., 380 kHz<br />
Retardo de respuesta aprox., 50 ms<br />
Tensión de trabajo, 10 ... 30 V CC<br />
Corriente en vacío, ≤ 50 mA
S/
0.00
0.0
PEN
Juego de transductores ultrasónicos clamp-on 0.5MHz FLEXIM 5m -40…130°C FM clase I Div 2
Juego de transductores ultrasónicos clamp-on 0.5MHz<br />
Marca: FLEXIM<br />
Modelo: TRF-FSK-NF2TS-050/TP<br />
Technical type, CDK1N52<br />
Longitud del cable: 5m<br />
Temperatura de la superficie del tubo -40…130°C<br />
Protección antideflagrante: FM clase I Div 2<br />
Incluye:<br />
-Pasta de acoplamiento Flexim -30...+200°C, tubo 10g.<br />
-Láminas de acoplamiento (-10...+200°C, 2 piezas)<br />
-Caja de paso para el cable de extensión del transductor de flujo,<br />
tipo JB04 sistema de conexión TS, FM Class I Div. 2 acero inox. SS316, IP 66,<br />
-Prensaestopas M20<br />
-50m cable de extensión, tipo 2615 ligbre de haógeno, piro-retardante<br />
-Acople acústico sólido libre de mantenimiento<br />
-Compensación de temperatura según ANSI/ASME MFC- 5.1M-2011<br />
-Certificado de calibración y SENSPROM
S/
0.00
0.0
PEN
Flujómetro no intrusivo permanente H721GP FLEXIM 20„32 V DC 4...20 mA Pt100/Pt1000
Flujómetro no intrusivo permanente H721GP<br />
Marca: FLEXIM<br />
Modelo: TF7-H721GP-F201S2-I2NNNNN-MTANN-LX/TP<br />
Interfaz, USB y Ethernet<br />
USB cable<br />
Protección antideflagrante: FM clase 1 Div.2<br />
Carcasa de acero inoxidable<br />
Alimentación de tensión: 20„32 V DC<br />
2x salida de corriente 4...20 mA, conmutable actica/ pasiva, galvanicamente separado<br />
Módulo de comunicación Modbus RTU<br />
Módulo de entrada de señal incl. 1 entrada de temperatura para Pt100/Pt1000<br />
Módulo de entrada de señal, incl. 1 entrada de corriente 0-20 mA, activa, utilizable como pasiva<br />
Manual de instrucción rápida
S/
28,341.74
28341.74
PEN
FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter L1+ HM Transducer, DN300 DN6000
Modelo: INT-100H + L1 + HM
• FLOWSONIC - CAUDALÍMETRO ULTRASÓNICO DE MANO / PORTÁTIL
• Marca (INTRIAL), Hecho en Taiwán para INTRIAL
• Precisión de medición del caudalímetro/calorímetro: mejor que el 1 %; Medidor Agua
• : mejor que el 2%; Medidor de calor: Estándar EN1434
• Repetibilidad Mejor que 0.2% o 0.5%
• Tipo de flujo: Agua, agua de mar, agua industrial, aceite líquido, aguas residuales y
• líquidos disponibles para ultrasonido.
• Velocidad ±0,03~±105 pies/s (±0,01~±32 m/s), bidireccional
• Material de la tubería Acero, acero inoxidable, hierro fundido, cobre, PVC, aluminio,
• Se permiten tubos de plástico reforzado con fibra de vidrio u otros tubos compactos y tubos revestidos.
• Temperatura del líquido 32° F~320° F (0° C~160° C)
• Interfaz de salida OCT, RS232
• Batería y alimentación: 3 baterías AAA Ni-H incorporadas, durará más de 12 horas de funcionamiento cuando están completamente recargadas.
• 90V-230VAC para el cargador
• Tipo de flujo: Agua, agua de mar, agua industrial, aceite líquido, aguas residuales y
• líquidos disponibles para ultrasonido
TRANSDUCTORES QUE INCLUYEN:
L1
• Type High-Heat L1
• Transductor de gran tamaño (magnético con abrazadera)
• Temperatura 0~160°C
• Para tamaño de tubería 11”~240”(DN300~6000mm)
HM
• Transductor de tamaño medio (magnético con bastidor de montaje)
• Dimensiones 11”*1.6”*1.6”(180*40*40mm3))
• Para tamaño de tubería 2”~28”(DN50~DN700mm)
S/
7,801.50
7801.5
PEN
FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter L2 + HM Transducer, DN300 DN6000
Modelo: INT-100H + L1 + HM
• FLOWSONIC - Handheld / Hand Hold Ultrasonic Flowmeter
• Brand (INTRIAL), Made in Taiwan for INTRIAL
• Measuring Accuracy Flowmeter/Calorimeter: Better than 1% ; Water meter: Better than 2%; Heat Meter: EN1434 Standard
• Repeatability Better than 0.2% or 0.5%
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
• Velocity ±0.03~±105ft/s(±0.01~±32m/s),bi-ditectional
• Pipe Material Steel, stainless steel, cast iron, copper, PVC, aluminum, glass reinforced plastics or other compact pipe and lined pipe allowed
• Liquid Temp 32 F~320 F (0 C~160 C)
• Output Interface OCT, RS232
• Battery and Power 3AAA Ni-H built-in batteries, when fully recharged, it will last over 12 hours of operation.
• 90V-230VAC for the charger
• Flow Type Water, sea water, industrial water, oil liquid, sewage and single liquid available for ultrasonic
TRANSDUCTORES QUE INCLUYE:
L1
• Type High-Heat L1
• Large size transducer(magnetic with clamp-on fixture)
• Temperature 0~160°C
• For pipe size 11”~240”(DN300~6000mm)
HM
• Medium size trasducer (magnetic with mounting rack)
• Dim 11”*1.6”*1.6”(180*40*40mm3))
• For pipe size 2”~28”(DN50~DN700mm)
S/
5,535.35
5535.35
PEN
SENSOR DE REPUESTO PARA FLUJOMETRO, Longitud de Cable: 30 pies (10 metros )
SENSOR DE REPUESTO PARA FLUJOMETRO SIERRA 205
Marca: Sierra Instruments (USA)
Longitud de Cable: 30 pies (10 metros )
S/
0.00
0.0
PEN
1