¡Bienvenido a Intrial! Equipos Industriales en Perú
Síganos
0
Mi carrito
PRODUCTOS
Contáctenos
0
PRODUCTOS
¡Bienvenido a Intrial! Equipos Industriales en Perú
Síganos
Contáctenos
Productos
Intrial Industrial
Automatización Industrial
Caudal
Precios en Soles
Precios en Soles
Ordenar por:
Destacado
Destacado
Novedades
Nombre (A-Z)
Precio - bajo a alto
Precio - alto a bajo
Caudal
All-Metal Variable Area Flowmeter, Range H2O:1000 - 10000 l/h
All-Metal Variable Area Flowmeter
Model: BGF-S50-206R-S-K-O-0-0-S-5-6-0-H
Brand: Kobold - Heinrichs
[BGF]: Model
[S50]: Stainless Steel, process temperature ≤ 200°C
[206R]: Connection, 2" Class 150 RF ASME B16.5-2003
[S]: Range (water 20°C, 1 mPas), H2O:1000 - 10000 l/h
[K]: Magnet bearer,Standard PP bis 80 °C
[O]: Flow direction, Top to bottom
[0]: Heating / cooling, without Heating / Cooling
[0]: Certificates, without
[S]: Display,
Standard display housing,
Process temperature ≤ 150°C for electrical output,
Process temperature ≤ 200°C for local indication
[5]: Scale, Measuring range-Scale (Media)
[6]: Switches, Transmitter ES with HART-protocol, 4-20 mA, EEx ia
Ambient temperature:-40° to +70°C
[0]: Accessories, without
[H]: Design, Heinrichs
S/
7,905.52
7905.52
PEN
All-Metal Variable Area Flowmeter BGF,Range (water 20°C, 1 mPas), H2O: 16.67-166.67 l/min,Process te
All-Metal Variable Area Flowmeter BGF
Brand: Kobold - Heinrichs
Model: BGF-S50-206R-S-K-L-0-0-S-2-0-0-K
[BGF-S50]:
Stainless Steel, process temperature ≤ 200°C
[206R]: Connection, size, 2" Class 150 RF ASME B16.5-2003
[S]: Range (water 20°C, 1 mPas), H2O: 16.67-166.67 l/min
[K]: Magnet bearer, Standard PP bis 80 °C
[L]: Flow direction, Left to right
[0]: Heating/cooling, without Heating / Cooling
[0]: Certificates, without
[S]: Display,
Standard display housing,
Process temperature ≤ 150°C for electrical output,
Process temperature ≤ 200°C for local indication
[2]: Scale, Measuring range-Scale (Water)
[0]: Switches, without
Ambient temperature, -40° to +80°C
[0]: Accessories, without
[K]: Design, Kobold
S/
5,201.00
5201.0
PEN
Transducer Clamp-on Ultrasonic Flow Meter, DN10..DN100, 2 MHz, 20 M
Model: DUC-WF-21-0-20
Brand: Kobold
[DUC-WF]:
Application area for stationary
flow velocity 0..2 m/s, 2-30 m/s
Temperature range -40..+150 °C
Sensor Housing PEEK/aluminium
Protection IP 68 (for stationary transducer)
Included Accessories Mounting rail, coupling foil, steel strap
[21]: for tube diameter, DN10..DN100, 2 MHz
[0]: Ex-approval¸ without
[20]: Cable length, 20 m
S/
5,264.16
5264.16
PEN
Transmitter Clamp-on Ultrasonic Flow Meter
Model: DUC-MF-1-7-0-S-RL
Brand: Kobold
[DUC-MF]:
Operating principle Ultrasonic
Mounting version stationary, wallmount
Measuring units volume flow, flow velocity, thermal output
Counter heat quantity, volume
Housing ABS
Additional input for heat measuring 2x Pt100
Output 2x4-20 mA, 1(2) pulse, 1x micro-USB, 1 relay;
optional RS232/RS485
Measuring channels 1, optional 2 channels
Protection IP 65
[1]: Measuring channels, 1-channel
[7]: Power supply, 18-36 VDC
[0]: Ex-approval, without
[S]: Language packages, german/spanish/french*
*only for 1-channel version
[RL]: Options, data logger*
*only for 1-channel version
S/
12,370.95
12370.95
PEN
Magnetic inductive flowmeter. Max. range (Water 20°C, 1 mPas), 62 m³/h. output 1: 4 - 20mA with HART
Magnetic inductive flowmeter
Model: EP-P-206R-2-H-H-1-0 / UMF2-A-1-4-G-0BK
Brand: Kobold - Heinrichs
[EP-P]:
Material - lining, PTFE (PFA)
Temperature, standard 3 Hastelloy electrodes, -20°C...150°C
[206R]: Process Connection, 2" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 62 m³/h
Installation length, 200 mm
[2]: Material flanges, stainless steel (1.4301)
[H]: Material electrodes, Hastelloy C-4, standard for PTFE
[H]: Earthing electrode (from DN20...), Hastelloy C-4, standard for PTFE
[1]: Transmitter mounting, integrated transmitter
Protection class sensor, IP67
[0]: Approvals, without
*****************************************************************
[UMF2-A]: Mounting IP67
integrated transmitter IP67 standard
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[4]: Power supply, 24V DC (±15%)
[G]: Output:
current output 1: 4 - 20mA with HART-protocol
pulse output: passive Um=24VDC
status output: passive Um=24VDC
[0BK]: Design, Kobold
******************************************************************
(2ea) Ground Disc / Sensor, DN50 / 2 inch
Material stainless steel
S/
10,149.38
10149.380000000001
PEN
Medidor de flujo de paletas rotativas (0,05-5,0 L/min)
Rotating Vane Flow Meter
Model: DRS-9-3-50-G5-F500
Brand: Kobold
[DRS-9]:
Operating principle Rotating vane
Mounting position all directions
Flow direction in direction of the arrow
max. temperature 80 °C
max. pressure 200/16 bar
Accuracy +/-1,5%
Protection IP 65
[3]: Material, plastic
[50]: Measuring range 0,05-5,0 L/min
[G5]: Mech. connection G 3/4 male
[F500]: Evaluating Electronic, Frequency output, 2m PVC-cable, PNP
S/
709.57
709.57
PEN
Variable Area Flowmeter,Shatter protection max. 80°C, without
Model: V31-60501S-01-D4W-B-F-S-0-0-2-0-0-0-0-0-0-0-K
Brand: Kobold – Heinrichs
[V31]:
[60501S]: Thread, NPT 1"(F) Verschraubung
Length, 375 mm, connection - wetted parts Edelstahl
[01]: Type of float, Material, Stainless steel 1.4571
guide rod 1.4571, without
[D4W]: Measuring range - stainless steel float with magnet, H2O: 95 - 950 l/h
1000kg/m³, 1mPas
[B]: Gasket, EPDM
[F]: Float Stop, PVDF
[S]: Union nut, Stainless steel
[0]: Shatter protection max. 80°C, without
[0]: Electrical output, without
[2]: Scale, Measuring range-scale (H2O)
[0]: Approvals, without
[0]: Calibration certificate, without
[0]: Cleaning according works standard (free of oil and grease), without
[0]: Pressure / leakage test, without
[0]: Approvals, without
[0]: Marking, without
[0]: Accessories, without
[K]: Make, KOBOLD
S/
2,336.74
2336.7400000000002
PEN
Indicador e interruptor de flujo con paleta y fuelle (G2 male)
Flow Indicator and Switch with Paddle and Bellows
Model: DWN-1-5-R50-X-R-T-0Brand: Kobold
[DWN-1]:
Operating principle paddle-bellow
Indication pointer w/o
Flow direction in direction of the arrow
Output 1 microswitch/SPDT, adjustable
max. temperature 100 °C
Connection male thread
[5]: Material combination, brass
[R50]: Connection, G 2 male
[X]: Signal lamp, without signal lamp
[R]: Flow direction, from right to left
[T]: Mounting pos. of indicat, above pipe
[0]: Options, w/o
S/
3,562.69
3562.69
PEN
Flow Indicator and Switch with Paddle and Bellows, 1 Microswitch/SPDT, G1
Model: DWU-1-6-R25-X-L-T-0
Brand: Kobold
[DWU-1]:
Operating principle paddle-bellow
Indication pointer indication
Flow direction in direction of the arrow
Output 1 Microswitch/SPDT
max. temperature 100 °C
Connection male thread
Electrical connection, PG 13,5
[6]: Material combination, st.st.
[R25]: Connection, G1 male
[X]: Signal lamp, without signal lamp
[L]: Flow direction, flow from left to right
[T]: Location of indicator, above lead
[0]: Options, w/o
S/
7,069.65
7069.650000000001
PEN
EP magnetic inductive flowmeter Max. measuring range (Water 20°C, 1 mPas), 62,4 m³/h
Model: EP-H-321B-1-S-S-3-0 / UMF2-G-1-1-G-0BK-4 / Ground Disc DN50
Brand: Heinrichs - Kobold
[EP-H]:
Material - lining, hard-rubber
standard 3 Hastelloy electrodes
Temperature 0°C...80°C
[321B]: Process Connection, DN50 PN40 Form B1 DIN EN 1092-1
Max. measuring range (Water 20°C, 1 mPas), 62,4 m³/h
Installation length, 200 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel
standard for hard rubber, soft rubber
[S]: Earthing electrode (from DN20...) Stainless steel
standard for hard rubber, soft rubber
[3]: Transmitter mounting remote transmitter
Protection class sensor, IP68, junction box via M20 x 1,5, encapsulated
add. junction box on Transmitter
[0]: Approvals, without
******************************************************************************************************
[UMF2-G]:
Mounting, remote transmitter
Connection to sensor, incl. 2,5m cable and wall mounting bracket
Thread - electrical connection, Transmitter c/w terminal connection box
½" NPT (f)
[1]: Display and control unit, integrated
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz
[G]: Output
current output 1: 4 - 20mA with HART-protocol
pulse output: passive Um=24VDC
status output: passive Um=24VDC
[0BK]: Design,Kobold
[4]: Extended cable length 20m
add. Junction box on transmitter
******************************************************************************************************
Ground Disc / Sensor DN50
******************************************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/ep_umf2b_db_en.pdf
S/
9,937.63
9937.630000000001
PEN
Contador de flujo de engranajes ovalados (30-450 L/min)
Oval Gear Flow Meter/Counter
Model: DON-1-35H-R9-4-Z2-N-0
Brand: Kobold (Alemania)
[DON-1]:
Operating principle Gear Wheel
Mounting position horizontal / vertical
Flow direction in direction of the arrow
max. temperature 80 °C
max. pressure 16...64 bar
Accuracy ±0,2 % …1 % of reading
Housing material Aluminium
Rotor material PPS
[35H]: Measuring range 30-450 L/min
[R9]: Mech. connection G 2
[4]: Seal NBR
[Z2]: Electronic, LCD batch controller
[N]: Cable entry 1/2 NPT
[0]: Options (please specify in clear text), without
S/
6,724.15
6724.150000000001
PEN
Compact Magnetic Inductive Flow Meter, 16...320 L/min, G 2 male
Model: MIK-6FC-65-A-G34R
Brand: Kobold
[MIK-6FC]:
Operating principle Magnetic Inductive
Mounting position all directions
Max. temperature/pressure 80 °C / 10 bar
Protection IP 65
Housing PVDF
Electrodes Hastelloy
Seal FFKM
[65]: Measuring range (liquid >30 µS/cm), 16...320 L/min, G 2 male
[A]: Connection set, without
[G34R]: Evaluation electronic for MIK
4-20 mA, 24 VDC, plug connection
S/
5,773.11
5773.11
PEN
Paddle Type Flow Switch
Model: PS-5214U
Brand: Kobold
Material Stainless Steel
Connection 1/2" NPT
Pipe Size, 4", 6", 8"
Increasing GPM (Water) 24...30, 53...75, 101...141
Decreasing GPM (Water) 19...27, 44...62, 88...123
Option, SPDT Switch, 5 Ft. Cable
***********************************************************************************
Datasheet: http://koboldusa.com/sites/default/files/product_files/Paddle-type-flow-switch.pdf
S/
828.45
828.45
PEN
Paddle Type Flow Switch PSE
Paddle Type Flow Switch
Model: PSE-12-149-N-15-R-1
Brand: Kobold
[PSE-12]:
Operating principle paddle
Mounting position horizontal
Approvals w/o
Body material st.st.
max. pressure* 250 bar
[149]: Measuring range/paddle, Paddle length: 114 mm(116 mm for NPT)
[N]: Connection, NPT-thread
[15]: Connection, 1/2"
[R]: Contact versión, N/O
[1]: Connecting cable, PVC-cable 1.5 m (standard)
S/
843.31
843.3100000000001
PEN
Oval Gear Flowmeter. Range by 10…800 mm2/s. Connection, 1/4 NPT. Accuracy +-2,5% FS. Electronic, Ana
Oval Gear Flowmeter
Model: OVZ-02-1-N2-N-L443
Brand: Kobold
Viscosity range: 10…800 mm2/s
Ambient temperature: -10°C…+60°C
Medium temperature: -10°C...+80°C
Max. pressure: 10 bar
[1]: Material: POM / POM / PN 10
[N2]: Connection: 1/4 “ NPT
[N]: Seals, NBR
[L443]: Electronic, Analogue output 4-20 mA, DIN-plug, 3-wire
***********************************************************
Datasheet: http://www.kobold.com/uploads/files/s4gb_ovz.pdf
S/
2,819.69
2819.69
PEN
Pelton Wheel Flow Meter, 20-80 L/min, 1 npt
Pelton Wheel Flow Meter
Brand: Kobold (Alemania)
Model: DPE-12-15-N6-C34P
[DPE-12]
Operating principle: Pelton Wheel (6-vane)
Mounting position / flow direction: in all directions/ in direction of the arrow
Protection: IP 65
Max. temperature: 80 °C
Max. pressure: PN 40 (DPE-1200W: 16 bar)
Accuracy of final value: +/-2,5%
Material Housing: St. St.
Material Axis Hard metal
[15]: Measuring range, 20-80 L/min
[N6]: Mech. connection, for MR-Code: 15, 1 NPT female
[C34P]: Electronic, Compact electronics, 4-20 mA, 1x PNP
S/
4,729.20
4729.2
PEN
EP magnetic inductive flowmeter Max. measuring range (Water 20°C, 1 mPas), 8 m³/h
Model: EP-H-202R-1-S-S-2-0 / UMF2-C-1-4-G-0BK-4
Brand: Kobold - Heinrichs
[EP-H]:Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[202R]: Process Connection, ¾" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 8 m³/h
Installation length, 200 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel
standard for hard rubber
[S]: Earthing electrode (from DN20...), Stainless steel
standard for hard rubber
[2]: Transmitter mounting remote transmitter
Protection class sensor, IP67, junction box via M20 x 1,5
cable >10m add. junction box on Transmitter
[0]: Approvals, without
***********************************************************************
[UMF2-C]: Mounting, remote transmitter
Connection to sensor, incl. 2,5m cable and wall mounting bracket
cable >10m c/w term.conn box on transmitter
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[4]: Power supply, 24V DC (±15%)
[G]: Output,
current output 1: 4 - 20mA with HART-protocol
pulse output: passive Um=24VDC
status output: passive Um=24VDC
[0BK]: Design, Kobold
[4]: Extended cable length, 20m, add. Junction box on transmitter
************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/ep_umf2b_db_en.pdf
S/
9,532.69
9532.69
PEN
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 38 m³/h. Installation length, 200mm.
Model: EP-H-205R-1-S-S-2-0 / UMF2-C-1-4-G-0BK-4
Brand: Kobold - Heinrichs
[EP-H]:Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[205R]: Process Connection, 1½" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 38 m³/h
Installation length, 200 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel
standard for hard rubber
[S]: Earthing electrode (from DN20...), Stainless steel
standard for hard rubber
[2]: Transmitter mounting remote transmitter
Protection class sensor, IP67, junction box via M20 x 1,5
cable >10m add. junction box on Transmitter
[0]: Approvals, without
***********************************************************************
[UMF2-C]: Mounting, remote transmitter
Connection to sensor, incl. 2,5m cable and wall mounting bracket
cable >10m c/w term.conn box on transmitter
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[4]: Power supply, 24V DC (±15%)
[G]: Output,
current output 1: 4 - 20mA with HART-protocol
pulse output: passive Um=24VDC
status output: passive Um=24VDC
[0BK]: Design, Kobold
[4]: Extended cable length, 20m, add. Junction box on transmitter
************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/ep_umf2b_db_en.pdf
S/
9,703.58
9703.58
PEN
EP magnetic inductive flowmeter,Temperature, 0°C...80°C , Process Connection, 4" Class 150 RF ASME
Model: EP-H-210R-1-S-S-2-0 / UMF2-C-1-4-G-0BK-4
Brand: Kobold - Heinrichs
[EP-H]:Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[210R]: Process Connection, 4" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 288 m³/h
Installation length, 250 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel
standard for hard rubber
[S]: Earthing electrode (from DN20...), Stainless steel
standard for hard rubber
[2]: Transmitter mounting remote transmitter
Protection class sensor, IP67, junction box via M20 x 1,5
cable >10m add. junction box on Transmitter
[0]: Approvals, without
***********************************************************************
[UMF2-C]: Mounting, remote transmitter
Connection to sensor, incl. 2,5m cable and wall mounting bracket
cable >10m c/w term.conn box on transmitter
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[4]: Power supply, 24V DC (±15%)
[G]: Output,
current output 1: 4 - 20mA with HART-protocol
pulse output: passive Um=24VDC
status output: passive Um=24VDC
[0BK]: Design, Kobold
[4]: Extended cable length, 20m, add. Junction box on transmitter
************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/ep_umf2b_db_en.pdf
S/
10,669.48
10669.48
PEN
Caudalímetro magnético inductivo (1896 m³/h)
EP magnetic inductive flowmeter
Model: EP-H-214R-1-S-S-2-0 / UMF2-C-1-4-G-0BK-4
Brand: Kobold - Heinrichs
[EP-H]:Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[214R]: Process Connection, 10" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 1896 m³/h
Installation length, 450 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel
standard for hard rubber
[S]: Earthing electrode (from DN20...), Stainless steel
standard for hard rubber
[2]: Transmitter mounting remote transmitter
Protection class sensor, IP67, junction box via M20 x 1,5
cable >10m add. junction box on Transmitter
[0]: Approvals, without
[UMF2-C]: Mounting, remote transmitter
Connection to sensor, incl. 2,5m cable and wall mounting bracket
cable >10m c/w term.conn box on transmitter
Thread - electrical connection, ½" NPT (f)
[1]: Display
S/
17,824.57
17824.57
PEN
27
28
29
30
31