Coriolis Massflowmeter. Range: min. min.0-1200 kg/h - max. 0-12000 kg/h. Output 1: 4 - 20mA with HA
Coriolis Massflowmeter
Model: TMU-S-015-201R-B-0-0-C-A-1-0-0-K / UMC4-D-2-A-2-1
Brand: Heinrichs - Kobold
[TMU-S]:
Wetted materials, Stainless steel
[015]: Meter line size, DN15 ANSI ½"
Range, min. 0-1200 kg/h - max. 0-12000 kg/h
[201R]: Process connection, ½" Class 150 RF ASME B16.5-2003
Installation length, 535 mm
[B]: Containment options, Standard containment with drain connection ½" NPT (f)
[0]: Heating / cooling, None
[0]: Connection for heating / cooling, None
[C]: Sensor configuration,Remote mount transmitter
Process temperature,-40° to 212°F, -40° to 100°C
Sensor Cable Connection, Terminal block via ½" NPT (f) IP66
[A]: Approvals, II 1/2G EEx ia IIC T6 - T2
[1]: Calibration flow, Standard, 3-point
[0]: Calibration density, None
[0]: Supplementary equipment, None
[K]: Design, Kobold
**********************************************************************
[UMC4-D]: UMC4-D-1-2-A-2-1
Mounting, Remote mount / terminal connection box, mounted
Conduit port opening,M20 x 1,5
[1]: Display / Interface board, Integral within transmitter housing, for ambient temperature up to 60°C
[2]: Power supply, 19 - 36V DC, 24V AC (±20%), 50/60Hz
[A]: Outputs
Analog output 1: 4 - 20mA with HART®
Analog output 2: 4 - 20mA
Pulse output: passive Um=30V DC
Status output: passive Um=30V DC
[2]: Approvals, II(1)2G Ex d [ia Ga] IIC T3-T4 Gb (terminal compartment Ex d), ambient to 60°C
[1]: Type of protection (signal output), Ex [ia Ga] intrinsically safe
*****************************************************************
S/ 29,266.77 29266.77 PEN
Coriolis MassflowmeterMProcess temperature,-40° to 212°F, -40° to 100°C,Pulse output: passive Um=30V
Coriolis Massflowmeter
Model: TMU-S-015-201R-B-0-0-C-A-1-0-0-K / UMC3-C-2-2-A-2-1-H
Brand: Heinrichs - Kobold
[TMU-S]: 
Wetted materials, Stainless steel 
[015]: Meter line size, DN15 ANSI ½"
Range, min. 0-1200 kg/h - max. 0-12000 kg/h
[201R]: Process connection, ½" Class 150 RF ASME B16.5-2003
Installation length, 535 mm
[B]: Containment options, Standard containment with drain connection ½" NPT (f)
[0]: Heating / cooling, None
[0]: Connection for heating / cooling, None
[C]: Sensor configuration,Remote mount transmitter
Process temperature,-40° to 212°F, -40° to 100°C
Sensor Cable Connection, Terminal block via ½" NPT (f) IP66
[A]: Approvals, II 1/2G EEx ia IIC T6 - T2
[1]: Calibration flow, Standard, 3-point
[0]: Calibration density, None
[0]: Supplementary equipment, None
[K]: Design, Kobold
**********************************************************************
[UMC3-C]: UMC3-C-2-2-A-2-1-H
Mounting, Remote mount
Sensor Cable Connection: terminal block via 1/2" NPT (f)
Conduit port opening, ½" NPT (f)
[2]: Display / Interface board, Remoteable, separate board plus panel mounting adapter kit
[2]: Power supply, 19 - 36V DC, 24V AC (±20%), 50/60Hz
[A]: Outputs
Analog output 1: 4 - 20mA with HART®
Analog output 2: 4 - 20mA
Pulse output: passive Um=30V DC
Status output: passive Um=30V DC
[2]: Approvals, II(1)2G EEx d [ia] IIB/IIC T3-T6 (Type of protection connection area EEx d), for ambient temperature up to 60°C
[1]: Type of protection (signal output), EEx ia
[H]:Design: Heinrichs
*****************************************************************
S/ 39,059.51 39059.51 PEN
Medidor de flujo magnético inductivo (288 m³/h)
EP magnetic inductive flowmeter
Model: EP-H-210R-1-S-S-1-0 / UMF2-A-1-1-F-0BK
Brand: Kobold-Heinrichs
[EP-H]: 
Material - lining: hard-rubber, standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[210R]: Process Connection, 4" Class 150 RF ASME B16.5-2003 
Max. measuring range (Water 20°C, 1 mPas), 288 m³/h 
Installation length, 250mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel,
standard for hard rubber, soft rubber 
[S]: Earthing electrode (from DN20...),  Stainless steel,
[1]: Transmitter mounting, integrated transmitter 
Protection class sensor, IP67
[0]: Approvals, without
****************************************************************
[UMF2-A]:
Mounting, IP67 integrated transmitter IP67 standard, ½" NPT (f)
[1]: Display and control unit, integrated
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz
[G]: Output:
current output 1: 0(4) - 20mA   with HART-protocol    
pulse output:  passive Um=24VDC      
status output: passive Um=24VDC
[0BK]: Design, Kobold
S/ 8,013.26 8013.26 PEN
EP magnetic inductive flowmeter
Model Sensor: EP-H-213R-1-S-S-1-0 / UMF2-A-1-1-G-0BK
Brand: Kobold – Heinrichs
[EP-H]:
Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[213R]: Process Connection, 8" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 1,118 m³/h
Installation length, 350 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel,
[S]: Earthing electrode, Stainless steel,
[1]: Transmitter mounting, integrated transmitter
Protection class sensor, IP67 
[0]: Approvals, without
********************************************************
[UMF2-A]:
Mounting, integrated transmitter IP67 standard
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz
[G]: Output:
current output 1: 4 - 20mA  with HART-protocol                                                                                            
pulse output:  passive Um=24VDC                                                                                                           
status output: passive Um=24VDC
[0BK]: Design, Kobold
S/ 13,009.93 13009.93 PEN
EP magnetic inductive flowmeter Max. measuring range (Water 20°C, 1 mPas), 38 m³/h
Model Sensor: EP-H-205R-1-S-S-1-0 / UMF2-A-1-1-G-0BK
Brand: Kobold – Heinrichs
[EP-H]:
Material - lining, hard-rubber
standard 3 stainless steel electrodes
Temperature, 0°C...80°C
[205R]: Process Connection, 1 1/2" Class 150 RF ASME B16.5-2003
Max. measuring range (Water 20°C, 1 mPas), 38 m³/h
Installation length, 200 mm
[1]: Material flanges, steel (painted)
[S]: Material electrodes, Stainless steel,
[S]: Earthing electrode, Stainless steel,
[1]: Transmitter mounting, integrated transmitter
Protection class sensor, IP67  
[0]: Approvals, without
********************************************************
[UMF2-A]:
Mounting, integrated transmitter IP67 standard
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz
[G]: Output:
current output 1: 4 - 20mA  with HART-protocol                                                                                             
pulse output:  passive Um=24VDC                                                                                                            
status output: passive Um=24VDC
[0BK]: Design, Kobold
S/ 7,047.36 7047.360000000001 PEN
Bypass+Direct Thermal Mass Flow Meter
Model: DMW-B2-5 46-G6-E-D-4
Brand: Kobold
[DMW-B2]:
Operating principle, Direct Thermal Flow
Mounting position all directions (horizontal recommended)
Indication LCD-display (Option)
Output 0-5 V or 4-20 mA
max. temperature 50 °C
max. pressure 10 bar
Sensor housing, st.st.
[5 46]: Tube / Measuring range, 56 mm, 0,20...4,0 m³n/min air
[G6]: Connection, Tube 56 mm / 84 mm: G 1
[E]: Seal, EPDM
[D]: Display/Protection class, display flow, IP40 
[4]: Output, 4-20 mA 
Option, dry and oil free
S/ 14,863.72 14863.720000000001 PEN
Bypass+Direct Thermal Mass Flow Meter Tube / Measuring range, 16 mm, 10,0...200,0 Ln/min air
Model: DMW-B2-2 25-G4-E-D-4
Brand: Kobold
[DMW-B2]:
Operating principle, Direct Thermal Flow
Mounting position all directions (horizontal recommended)
Indication LCD-display (Option)
Output 0-5 V or 4-20 mA
max. temperature 50 °C
max. pressure 10 bar
Sensor housing, st.st.
[2 25]: Tube / Measuring range, 16 mm, 10,0...200,0 Ln/min air  
[G4]: Connection, Tube 16 mm / 32 mm: G 1/2
[E]: Seal, EPDM
[D]: Display/Protection class, display flow, IP40  
[4]: Output, 4-20 mA  
Option, dry and oil free
S/ 8,719.11 8719.11 PEN
Plastic Flowmeter-switch. Range: 1200...12000 L/h water. Accuracy, ±4 % FS. connection R 2 ¾ male. M
Model: KSM-2-120-H-000-R0
Brand: Kobold
[KSM-2]:
Operating principle, variable area
Mounting position, vertical
Flow direction, from bottom
Armature material, Polysulfone
Accuracy, ±4 % FS
Max. temperature, 100 °C*
* 60 °C c/w PVC-connection
Max. pressure, 16 bar
[120]: Measuring range: 1200...12000 L/h water
[H]: Scales for liquid media, L/h water
[000]: Option connection for size 120: R 2 ¾ male
[R0] Option contact: w/o contact
S/ 2,113.84 2113.84 PEN
Oval Gear Flow Meter/Counter
Model: DON-2-60H-AC-1-E3-T-0
Brand: Kobold
[DON-2]:
Operating principle Gear Wheel
Mounting position horizontal / vertical
Flow direction in direction of the arrow
max. Temperature 120 °C*
max. Pressure 16…100 bar
Accuracy ±0,2 % …1 % of reading
Housing material st. steel
Rotor material st. steel
[60H]: Measuring range, 150-2500 L/min 
[AC]: Mech. Connection, ANSI flange 4" 150 lbs 
[1]: Seal, FKM 
[E3]: Electronic, Z3 electronic with ATEX approval (Exi) 
[T]: Cable entry, 1/2 NPT with cooling fin  for electronic Z.. and E...  
[0]: Options (please specify in clear text), without
S/ 45,820.81 45820.81 PEN
Caudalímetro magnético inductivo (62 m³/h)
EP magnetic inductive flowmeter
Model Sensor: EP-H-206R-1-S-S-1-0 / UMF2-A-1-1-G-0BK
Brand: Kobold – Heinrichs 
[EP-H]:
Material - lining, hard-rubber 
standard 3 stainless steel electrodes 
Temperature, 0°C...80°C 
[206R]: Process Connection, 2" Class 150 RF ASME B16.5-2003 
Max. measuring range (Water 20°C, 1 mPas), 62 m³/h 
Installation length, 200 mm 
[1]: Material flanges, steel (painted) 
[S]: Material electrodes, Stainless steel, standard for hard rubber, 
soft rubber 
[S]: Earthing electrode (from DN20...), Stainless steel,
standard for hard rubber, soft rubber  
[1]: Transmitter mounting, integrated transmitter 
Protection class sensor, IP67  
[0]: Approvals, without[UMF2-A]: 
Mounting, integrated transmitter IP67 standard 
Thread - electrical connection, ½" NPT (f)
[1]: Display and control unit, integrated
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz
[G]: Output:
current output 1: 4 - 20mA  with HART-protocol                                                                                             
pulse output:  passive Um=24VDC                                                                                                            
status output: passive Um=24VDC
[0BK]: Design, Kobold
S/ 7,262.83 7262.83 PEN
Viscosity Compensated Flow Meter/ Monitor, 2 - 6 L/MIN, G1/2
Model: VKA-3104-R0-R15-B
Brand: Kobold
[VKA-3104]:
Max. temperature: Ambient -25...+75°C
Medium -25... +100°C
Flow meter/monitor with 1 contact
Measuring range L/min Oil*, 2 - 6
*Mearuring ranges in L/min water on request 
[R0]: Contact, 1 N/O contact
[R15]: Connection female, G 1/2 (upto VKA-..04)
[B]: Mounting position, from bottom to the top
S/ 2,243.86 2243.86 PEN
Paddle Wheel Flow Sensors DF Sensor
Paddle Wheel Flow Sensors DF Sensor
Model: DF-0405
Brand: Kobold
DF Flow Sensor Material Combination: IV
Range (Water): 0.2...2.5 GPM
Stand. Conn. (NPT), 3/8"
Dia. of Orifice (Inch), 0.19
Press. Drop Max. (PSI) 12.1
S/ 3,436.38 3436.38 PEN
Paddle Wheel Flow Sensors Kobold 3/4"NPT
Paddle Wheel Flow Sensors
Brand: Kobold(USA)
Model: DF-0407
Power Supply: 5 to 24 VDC
Signal Output: NPN - Open Collector 10 mA max.
Temperature Range: -4...176 °F
Protection: IP 65
Accuracy: ± 2.5% of F.S.
DF Flow Sensor Material Combination: IV
Range (Water): 0.5...6 GPM
Stand. Conn. (NPT), 3/4" 
Dia. of Orifice (Inch), 0.32
Press. Drop Max. (PSI) 4.4
S/ 3,711.29 3711.29 PEN
Calibration Certificate for DWU
Calibration Certificate for DWU:
Model: DWU-36-W1F-X-L-T-X
Model: DWU-36-W3H-X-L-T-X
S/ 278.63 278.63 PEN
Flow Indicator and Switch with Paddle and Bellows, 1 NPT, 1 Microswitch/SPDT, SS
Model: DWU-1-6-N25-X-L-T-0
Brand: Kobold
[DWU-1]:
Operating principle paddle-bellow
Indication pointer indication
Flow direction in direction of the arrow
Output 1 Microswitch/SPDT
max. temperature 100 °C
Connection male thread
Electrical connection, PG 13,5
[6]: Material combination, st.st.
[N25]: Connection, 1 NPT male
[X]: Signal lamp, without signal lamp
[L]: Flow direction, flow from left to right
[T]: Location of indicator, above lead
[0]: Options, w/o
S/ 7,032.50 7032.5 PEN
Rotating Vane-Flowmeter with Pulse Output Measuring range, 2...48 L/min water
Model: DF-D-48-D-N20-DLK-3-4
Brand: Kobold
[DF-D]:
Operating principle Rotating Vane
Mounting position horizontal / vertical
Flow direction in direction of the arrow
Max. temperature s. material combination
Max. pressure s. material combination
Accuracy +-2,5% FS
Model batch contr. analogue relay
[48]: Measuring range, 2...48 L/min water
[D]: Material combination, Housing/ cover/ connection/ Temp./ pressure
Brass/ Polysulfone/ brass/ 80 °C/ 16 bar  
[N20]: Connection** Material combination code: A/D/G, 3/4 NPT
** NPT-thread same price (Code: N..; e.g.: N15 for 1/2 NPT)
[DLK]: Model of electronic, LC-Display, 1.5 m cable  
[3]: Power supply, 24 VDC  
[4]: Analogue output 0(4)...20 mA
S/ 2,953.43 2953.43 PEN
Low Volume Flowmeter,Connection size : 1/8" NPT female on rear ( or 1/4" NPT female*) ,Max. temperat
Low Volume Flowmeter
KOBOLD ALEMANIA
KFR-4150-N0
{KFR-41}
Operating principle : variable area
Mounting position : vertical
Flow direction :from bottom
Total length :165 mm 
Accuracy :±3 % FS 
Max. temperature : 65 °C
65 °C: 6,5 bar
Housing : Acryl
Connection material : brass 
Connection size : 1/8" NPT female on rear ( or 1/4" NPT female*) 
Seal :NBR 
{50}: Measuring range , 40...400 cm³/min water 
{NO}: Options , w/o
S/ 679.85 679.85 PEN
Flujómetro Magnético Inductivo Compacto (3,2...63 L/min)
Compact Magnetic Inductive Flow Meter
Model: MIK-6FC-50-K-L343
Brand: Kobold (Alemania)
[MIK-6FC]:
Operating principle Magnetic Inductive
Mounting position all directions
Max. temperature/pressure 80 °C / 10 bar
Protection IP 65
Housing PVDF
Electrodes Hastelloy 
Seal FFKM 
[50]: Measuring range (liquid >30 µS/cm), 3,2...63 L/min, G 1½ male 
[K]: Connection set, PVC-glue connection, G 1½ - Ø26/32 mm 
[L343]. Evaluation electronic for MIK, 
Analogue output  24 VDC, 4-20 mA, plug M12, 3-wire
S/ 3,662.99 3662.9900000000002 PEN
Bypass+Direct Thermal Mass Flow Meter
Model: DMW-A7-153-G2-F-D-4
Brand: Kobold
[DMW-A7]:
Operating principle thermal, Bypass
Mounting position all directions (horizontal recommended)
Indication LCD-display (Option)
Output 0-5 V or 4-20 mA
max. temperature 50 °C
max. pressure 10 bar
Sensor housing Aluminium
[153]: Tube / Measuring range, small, 0,25...5,00 Ln/min air 
[G2]: Connection, Tube small / 4 mm / 8 mm: G 1/4 
[F]: Seal: FPM
[D]: Display/Protection class, display flow, IP40 
[4]: Output: 4-20 mA
S/ 6,103.75 6103.75 PEN
Bypass+Direct Thermal Mass Flow Meter Tube / Measuring range, small, 0,25...5,00 Ln/min air
Model: DMW-A7-153-G2-F-3-4
Brand: Kobold
[DMW-A7]:
Operating principle thermal, Bypass
Mounting position all directions (horizontal recommended)
Indication LCD-display (Option)
Output 0-5 V or 4-20 mA
max. temperature 50 °C
max. pressure 10 bar
Sensor housing Aluminium
[153]: Tube / Measuring range, small, 0,25...5,00 Ln/min air  
[G2]: Connection, Tube small / 4 mm / 8 mm: G 1/4  
[F]: Seal: FPM
[3]: Display/Protection class, w/o display, IP40  
[4]: Output: 4-20 mA
S/ 5,156.42 5156.42 PEN