HANDHELD FLUE GAS COMBUSTION ANALYZER, Display 4, O2: 0 to 21%; CO: 0 to 2000 ppm (4000 ppm max for
HANDHELD FLUE GAS COMBUSTION ANALYZER
Brand: DWYER(USA)
Rotary Dial Selection, Display 4 Parameters Simultaneously
Range: O2: 0 to 21%; CO: 0 to 2000 ppm (4000 ppm max for 15 minutes);
CO2: 0 to 30%; Temp. (flue and net): 32 to 1112°F (0 to 600°C)
Efficiency: 0 to 99.9%; Excess air: 0 to 250%.
Accuracy: O2: ±0.2%; CO: ±10 PPM
< 100 PPM else ±5% of reading;
CO2: ±0.3% reading; Temp. (flue and net): ±2°C ±0.3% reading;
Efficiency: ±1% reading; Excess air: ±0.2%.
Resolution: O2: 0.1%; CO: 1 PPM;
CO2: 0.1%; Temp. (flue and net):
0.1°F/C; Efficiency: 0.1%; Excess air: 0.1%.
Ambient Operating Temperature: 32 to 104°F (0 to 40°C).
Power Requirements: (8) AA
alkaline batteries, installed functional,
user replaceable, (4) AA NiMH batteries,
included, user replaceable (charger
included) or optional power adapter.
Pre-Programmed Fuels: Natural gas,
light oil, propane, butane, LPG, and wood pellets.
Probe: 11.8 (300 mm) length x 0.25 (6 mm) diameter with 7.8 (200 mm)
stainless steel shaft.
Hose: 10 ft (3 m).
Weight: 1.7 lb (0.77 kg).
Agency Approvals: CE.
S/
5,587.12
5587.12
PEN
Sensor Infrarojo de Metano (Chincha)
Sensor Infrarojo de Metano, Filament Detector
Incluye:
Sensor Infrarrojo de Methano (093-0500)
Filament Detector Guard Assembly (Combustible).(096-3363)
S/
1,814.00
1814.0
PEN
Multi-Gas Detector, %LEL, O2, H2S, CO
• BW Technologies GasAlert MicroClip XL Multi-Gas Detector
• Number of Gases: Four(4)
• Gas: Combustible, Oxygen, Hydrogen Sulfide & Carbon
• Monoxide
• (%LEL, O2, H2S, CO)
• Color: Black
• Size 4.4 x 2.4 x 1.2 in. /11.3 x 6.0 x 3.1 cm
• Weight 6.7 oz. / 190 g
• Temperature -4 to +122°F / -20 to +50°C
• Typical battery life 18 hours (recharges in less than 6 hours)
o Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C.
• Ingress Protection IP68
• Certifications and
• approvals n Class I, Div. 1, Gr. A, B, C, D
• ATEX: X g II 1 G
• Ex ia IIC T4 Ga
• IECEx: Ex ia IIC T4 Ga
• X: European Conformity
• Standard Package Contents
• Detector complete with specified sensor(s), stainless steel alligator clip and concussion-proof housing
• Rechargeable battery
• Wall outlet charging adaptor
• Calibration/test cap and hose
• Manual
• Multi-language CD manual
S/
3,446.60
3446.6
PEN
Detector de Gas Portátil PS500, O2, CO, CO2, NO2
Model :61168
• Any combination of (O2/CO/CO2/NO2)
• Audible, visual and vibrating alarms
• Fully certified
• Internal pump (optional)
• Run up time up to 80 hours, when using low power LEL sensor (optional)
• Lightweight
• Sensor integrity checking
• Robust construction
• Ease of maintenance
S/
9,051.86
9051.86
PEN
MultiExact 4100 (0-10-50vpmCO y 0-50-500pmCO2)
MultiExact 4100 (08100A1-SP6050US- MultiExact 4100)
A.- Especificaciones:
• Con la siguiente configuración:
• Sistema de muestra impulsado por flujo
• MÓDULO 1: Medición 0-10 / 50vpm CO
• Tecnología: Infrarrojos (Gfx)
• Rango: 0-50 / 0-500ppm, 0-10 / 0-50ppm † "
• Precisión (error intrínseco): "1% de la lectura o <0,5 ppm
• Repetibilidad "1% de rdg o <0.5ppm *"
• "Desviación cero / semana" 1 ppm
• T90 en segundos <20 a 2000 ml / min
• Alarmas configurables Dos alarmas
• Salida analógica aislada 4-20 mA aislada
• MÓDULO 2: Medición 0-50 / 500vpm CO2
• Gas CO2 (traza)
• Tecnología Infrarrojos (Gfx)
• Rango 0-5 / 0-100ppm
• Precisión (error intrínseco): "1% de la lectura o <0,1 ppm *" "
• Repetibilidad "1% de rdg o <0.1ppm *"
• "Deriva cero / semana" 0,2 ppm
• T90 en segundos <20 a 2000 ml / min
• Alarmas configurables Dos alarmas
• Salida analógica aislada 4-20 mA aislada
• CONFIGURACIÓN GENERAL.
• Cable de alimentación para Europa
• Montaje en bastidor con orejas
• Contactos de relé 4 contactos de relé
B.- Certificaciones:
• EN 61010-1: Requisitos de seguridad para equipos eléctricos de medición, control y uso en laboratorio
• EN 61326-1: Equipos eléctricos para medición, control y uso en laboratorio.
• Requisitos de EMC
• Categoría de instalación II clasificado de acuerdo con IEC664
C.- Tamaño:
• 132,5 mm (5,2 ") de altura
• 265,5 mm (10,5 ") de altura con chasis de expansión)
• 481,6 mm (19 ") de ancho
• 544,2 mm (21,4 ") de profundidad
• Peso:
• Unidad principal: aproximadamente 14 kg (30,9 lb)
• Chasis de expansión: aproximadamente 13,7 kg (30,2 libras)
• (depende del número y tipo de sensores utilizados)
• Temperatura de funcionamiento: 5C - 40C (41F - 104F)
S/
93,965.20
93965.2
PEN
GASMAX EC Gas Monitor (0 - 50 ppm Cl2)
GASMAX EC Gas Monitor, Loop-Powered Gas Monitor for Toxic Applications
- Power Input 10-30VDC at less than 0.75 watts
- Display 64 x 128 pixel LCD with 30-minute trend, bargraph and
- engineering units display.
- Input Accepts microamp-level signals from local or remote
- GDS Corp toxic or oxygen deficiency sensors
- Accuracy +/- 5% of full scale range (typical)
- Standard
- Output
- Standard 2-wire 4-20mA current sink output. Max loop R
- is 600 ohms with nominal 24VDC power supply.
- Temp Electronics -40°C to +60°C. See Echem Sensor Manual
- for additional information
- Housing Aluminum housing with epoxy paint standard; #316
- stainless steel optional
- Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5”
- (127 mm) Shipping weight 6.5 pounds (3 kg)
- Approvals CSA Certified Div 1 & 2 Groups B, C, D. Suitable for
- explosion-proof installations
- CSA Certified Div 1 & 2 Groups A, B, C, D. Intrinsically
- safe. IMPORTANT: Intrinsically Safe installations
- require IS barrier #10-0263 (MTL 7787P+) or equivalent.
- ATEX Certified EX II 2 G EEx d IIB + H2 T5
- Warranty Two years on electronics and one year on sensors.
//////////CODIGOS PARA ORDENAR///////
- GM-EC: GASMAX EC Gas Monitor, Loop-Powered Gas Monitor for Toxic Applications
- 3: Sensor Head (Local sensor head for reactive gases IS)
- 12: Sensor Type (chlorine)
- 5: Target Gas Range (0 - 50 ppm)
S/
0.00
0.0
PEN
GASMAX II Gas Monitor - Detector ( 0 -100 % LEL METHANE)
GMII: GASMAX II Gas MonitorSingle / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Location Chanel 1
0: Sensor Head (No sensor head)
00: Senor Type (No sensor)
0: Target Gas Range (None)
Chanel 2
2: Sensor Head (Local sensor head with splash guard)
50: Senor Type (SmartIR 0 to 100% LEL Methane)
6: Target Gas Range (0 - 100% LEL)
Output
0: standard 4 -20 ma output (3-wires)
0: standard temperature range
GASMAX II Gas Monitor Single / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations
Power Input: 10-30VDC at < 4 watts with relay board. Additional power required for Extended Temp & GDS-IR option.
Display: Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph
Electrochemical Sensor Input: Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors or 4-20mA current source
Bridge Type Sensor Input: Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead or 4-20mA current source
Standard Output: Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Outputs: Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC; Single or dual MODBUS slave ports; 3x program-mable alarm relays with 5A capability
Temp: Electronics -40°C to +60°C; See Echem Sensor Manual for sensor limits
Housing : Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
Dimensions: Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals: CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP installations
Warranty: 2 years on electronics and one year on sensors
S/
6,893.20
6893.2
PEN
Conjunto de escudo contra clima
Numero de parte: 40012041
Conjunto de Escudo contra clima
Marca : Scott
S/
507.92
507.92
PEN
DF 310E PROCESS OXYGEN ANALYSER -SPECIAL
DF 310E PROCESS OXYGEN ANALYSER -SPECIAL
Brand: SERVOMEX
With the following configuration:
Sensor Basic Sensor
Resolution High
Single Range 0-100 ppm
Power Input 110 VAC Input Power
Battery Backup Not Required
Certification CE Certified
Sensor Location Local Sensor
Pump No Pump
Case Purge Not Required
Mounting / Cabinet Dual Rack Mount
Key Lock Not Required
Flow Alarm Required
Relay Contacts Two Relay Contacts
Sample Inlet Stainless Steel (Standard)
Isolated Output 4-20mA with live zero (2-20mA)
Stainless Steel Tags Required
Electrolyte Type Blue
DF310E-OEM-0020-DRM-1
As above with:
310E-ROTM ROTAMETER
310E-FLEX-FA FLEXIBLE OUTLET TUBING FOR FLOW ALARM
15437110 ASSEMBLY, STANDARD CABINET DF310E
50980707 CONN, TERM BLK, 8 PIN 1757077 PHOENIX
50980755 PLUG, 4 PIN, 5.08mm PHOENIX 1757035
50980708 PIN, CODING, 1759994, PHOENIX
NSQ-0265-MTL
NSQ-0311-JS
NSQ-0313-JS
S/
54,057.20
54057.200000000004
PEN
Detector de Gas Portátil PS200, LEL, O2, CO y H2S
• Simple 1-button operation
• Any combination of (LEL/O2/CO/H2S)
• Audible, visual and vibrating alarms
• Fully certified
• Internal pump (optional)
• Run up time up to 80 hours, when using low power LEL sensor (optional)
• Lightweight
• Sensor integrity checking
• Robust construction
• Ease of maintenance
S/
3,591.72
3591.7200000000003
PEN
Display Spare Kit
Modelo : 05000950
Display Spare Kit
for 5200 portable gas analyzer- Servomex
S/
3,591.72
3591.7200000000003
PEN
Particulate Filter, 2 µm
Modelo: 2377-3831
(Particulate Filter, 2 µm, 1/8" Connections)
•T-Type
•Particulate Filter, 2 µm
•Max pressure: 6000 psi
•For use with 4100 series, Zirconiza sensor from Servomex
///Servomex Part Numer: 2377-3831/////
S/
1,777.72
1777.72
PEN
Valve Inlet,0.5 LPM)(1500 PSI / 10000 kpa)
70-SS-0.5 LPM
• Brand Intrial
• Valve Inlet: C-10
• Flow Rate: 0.5 LPM FIXED
• Gauge PSI: 1500 PSI / 10000 kpa
• Material: Stainless Steel
• Fits Cylinder: 34L Aluminum, 58L Aluminum, 74L Aluminum, 116L Aluminum
• ecosmart™: 44ES Aluminum, 66ES Aluminum
S/
1,269.80
1269.8
PEN
Flow sensor - stainless steel compatible
• Flow sensor - stainless steel compatible (S1760000)
• Brand: (Servomex)
S/
6,893.20
6893.2
PEN
Oxygen sensor assembly, with 357 cell
• Oxygen sensor assembly, with 357 cell (01160702)
• Brand: (Servomex)
S/
21,405.20
21405.2
PEN
Measuring cell, corrosive and/or high pressure use
• Measuring cell, corrosive and/or high pressure use (00357000)
• Brand: (Servomex)
S/
15,419.00
15419.0
PEN
Detector de Combustible IR, 0 – 100 % LEL, NEMA 4X, IP66, 3 alarmas, 10-30 VCC,
Modelo: 096-3480-01 + 096-3473-56
///Medidor/Detector de Gases Combustibles (LEL), Versión Compacta///
Especificaciones Exactas del modelo cotizado
///096-3480-01///: ALUMINUM ENCLOSURE, STANDARD DISPLAY, PLASTIC END
CAP (Transmisor Universal que se puede usar para todo tipo de Sensores)
///096-3473-56///: ///MERIDIAN COMBUSTIBLE INFRARED SENSOR(Sensor de
Combustible Infraroja, de larga vida Útil///
Rango de medición: ///0 – 100 % LEL///(AUTO-AJUSTABLE)
Material de la carcasa: ///Aluminio libre de cobre///
Voltaje de servicio 3/4 hilos: /// 10-30 VCC (24 VCC nominal)///
Protección de la carcasa NEMA 4X, IP66
Alarmas: 3 alarmas programables con inicio y reseteo (banda muerta ajustable);
MERIDIAN COMBUSTIBLE INFRARED SENSOR,
///096-3473-56///: ///MERIDIAN COMBUSTIBLE INFRARED SENSOR(Sensor de
Combustible Infraroja, de larga vida Útil///
Rango de medición: ///0 – 100 % LEL///(AUTO-AJUSTABLE)
Hoja técnica :
https://app.box.com/s/bbkinwyle85zmed6hvgwuv169yd0ypf4
S/
6,719.06
6719.06
PEN
-Keypad completely with power switch and key switch for Biolyzer
-Keypad completely with power switch and key switch for Biolyzer
-Brand: AFRISO
S/
1,777.72
1777.72
PEN
SERVOMEX Paramagnetic O2 de alta Pureza 0.1
SERVOPRO 4100 Gas Purity Analyser
With the following configuration:
Voltage UK 170-264V 50/60Hz
Background Gas N2
Module 1 Paramagnetic O2 , 0.1% precision for Medical and Industrial Purpose
Sample System Module 1 Flow Driven
Back Pressure Valve Module 1 Not required
Chassis Type short Chassis
Right Flowmeter 500ml/min Fitted to Module 1
Internal Sample Filter Internal Fitted to Module 1
Autocalibration Internal Autocal Pm Module 1
Mounting 19" Rack Mount Ears Only
User Manual Spanish
S/
32,289.20
32289.2
PEN
SERVOPRO 4100 Gas Purity Analyser 04100C, (1000ppmCO
Modelo : 04100C1(1000ppmCO)-Praxair
· CHASSIS TYPE: Long Chassis (2 long sensor modules)
· Long Sensor Modules 1: **Simplified SIPS GFX CO 0-100/1000vpm**
· Flow Driven GFX for sensor 1
· FLOWMETER (LEFT): 2500ml Flowmeter for Module 1
· MOUNTING: Bench Mount, 19" Rack ears only
· POWER: EUR 170-264V AC