Kit espejos Opticos
Kit Espejos Opticos
S/ 5,202.48 5202.4800000000005 PEN
Kit ventanas opticas
Kit Ventanas Opticas
S/ 3,049.91 3049.91 PEN
TRANSFORMADOR 2TX
TRANSFORMADOR 2TX
Brand: SERVOMEX
S/ 3,584.46 3584.46 PEN
Kit, IR Source
·         Kit, IR Source
·         GFX SOURCE ASSY
S/ 19,440.13 19440.13 PEN
Kit, Gfx1210 Fuses Spare
Kit, Gfx1210 Fuses Spare
Kit 1210 FUSES
S/ 605.73 605.73 PEN
S/ 2,117.05 2117.05 PEN
Spare Power Supply Unit (ATEX)
SPARE POWER SUPPLY UNIT (ATEX)
Brand: SERVOMEX
S/ 6,893.20 6893.2 PEN
Accesorio Gas Calibración Vinyl Tubing
Non-Reactive Tubing (Tubing-Tygon)
S/ 18.14 18.14 PEN
Filter Coal w/Hydroph Membr Viton/SS
Modelo:           201867
•    Filter Coal w/Hydroph Membr Viton/SS
•    For 2200 series analyzer panel system on ISALMET
S/ 2,866.12 2866.12 PEN
SERVOPRO-MULTIEXACT-4100, O2Purity
SERVOPRO-MULTIEXACT-4100(O2Purity)
GAS PURITY ANALYSER (SERVOPRO MultiExact 4100)
Supply: European Power Lead
Gas Module 1: Paramagnetic O2 Purity (0-100% O2)
Module 1 Flowmeter:  500ml/min (Sample)
Module 1 Filter  
Filter Required
Analogue Outputs: Gas Module 1 mA Analogue Output    
Mounting: 19" Rack Mount Ears Only
MONITORING PERFORMANCE
Accuracy (intrinsic error) <0.01% O2
Repeatability <0.01% O2
Zero drift/week <0.01% O2
T90 in secs <10@200ml/min
 
S/ 50,429.20 50429.200000000004 PEN
SERVOPRO MULTIEXACT 4100, 500ppmCO2, 500ppmCO
SERVOPRO-MULTIEXACT-4100(CO-CO2-ppm)
• GAS PURITY ANALYSER (SERVOPRO MultiExact 4100)
• Supply European Power Lead
• Gas Module 1: 1210D GFX 0-50/500vpm CO2, Infrared (Gfx)
• Gas Module 2: 1210D GFX 0-50/500vpm CO, Infrared (Gfx)
• Module 1 Flowmeter: 2500ml/min (Sample) 1210D
• Module 2 Flowmeter: 2500ml/min (Sample) 1210D
• Analogue Outputs: Gas Module 1 mA Analogue Output    
• Analogue Outputs: Gas Module 2 mA Analogue Output          
• Mounting: 19" Rack Mount Ears Only
• MONITORING PERFORMANCE
S/ 122,989.20 122989.2 PEN
​CARBON MONOXIDE TRANSMITTER, 0 to 125 PPM CO., ±2.5% of reading., -4 to 104°F
CARBON MONOXIDE TRANSMITTER
Brand: DWYER(USA)
[CMT-WR-WP]: model, configuration: NEMA 4X Wall.
External Display: No
Alarm/Buzzer: Yes
Range: 0 to 125 PPM CO.
Accuracy: ±2.5% of reading.
Repeatability: ±1% of reading.
Response Time: Less than 60 seconds typical for 90% step change.
Ambient Operating Temperature: -4 to 104°F (-20 to 40°C).
Ambient Operating Humidity: 15 to 90% non-condensing.
Power Requirements: 24 VDC/VAC at 100 mA.
Internal Display: Two line 8-digit alphanumeric LCD.
Sensor: Electrochemical (2 to 3 year expected life typical).
Output: Current/voltage: 4 to 20 mA and 2 to 10 VDC; Optional relay: (2) SPDT 1 Amp dry contact; Buzzer: 85 dB @ 1 foot.
Coverage Area: 7500 square feet (max).
Weight: 5.7 oz (161.6 g).
S/ 0.00 0.0 PEN
Kit, Filter Elements 6 micron Spare
• Filter Elements 6 micron Spare (For 4100 series)
S/ 0.00 0.0 PEN
Spare: Cell H2S x2 (ppm levels)
Spare: Cell H2S x2 (ppm levels)
Para analizador “HS2-725-22-4”
Marca: SOUTHLAND SENSING
S/ 3,410.32 3410.32 PEN
Analyzer with System H2S, Range 0-2000 ppm
ANALYZER WITH SYSTEM
Brand: SOUTHLAND SENSING
In-Line H2S Analyzer-
Range 0-2000 ppm
Model HS2-725-22-4
Includes ¼”Swagelok valve for sample and calibration
Flowmeter
Fittings and tubing integrated
The H2S analyzer is designed to meet the standards for
Class 1, Div 1, Groups B,C,D.
Nota.- Inclutre Filtro Coalescente
S/ 35,917.20 35917.200000000004 PEN
TARJETA CONEXIÓN
Connection Board
S/ 0.00 0.0 PEN
GAS ANALYSER ,SERVOPRO SO2, 20ppm
4900 MultiGas
With the following configuration:
Analyser Reference 08900A1-929XXXXXX
Series Code 4900 MultiGas
MODULE 1 .
Measurement 0-100/1000vpm SO2
Plumbed in Stream 1
Configurable Alarms Two Alarms (Std)
Isolated Analogue Output Isolated 4-20mA
0-10 VDC Output 0-10 VDC
Dual Analog Output Single
Digital Input Not Required
Isolated Analogue Input Not Required
MODULE 2 .
Measurement None
MODULE 3 .
Measurement None
MODULE 4 .
Measurement None
GENERAL CONFIGURATION.
Power Cord Europe
Flow Alarm Not Required
Left Flowmeter (Stream 1) 2500ml/min
Right Flowmeter (Stream 2) Not Required
Serial Communications RS232 Communication
Modbus TCP/IP Not Required
Mounting Rack Mount w/ears
Autocal Not Required
Relay Contacts 4 Relay Contacts (Std)
Operator Manual English
Extended Chassis Not Required
S/ 54,057.20 54057.200000000004 PEN
GAS PURITY ANALYSER, SERVOPRO MultiExact 4100)((02%Purity-O2ppm-Zirconia)

Analyser Reference 08100A1-1110CXX0AXXXXXXXXXXXX
Series Code MultiExact 4100
Type Standard N2 Background
Sample System Flow Driven
  MODULE 1 .
Measurement O2 Trace
Flowmeter Not Required
External S/S Filter Required w/ Standard Filter
Configurable Alarms Two Alarms
Isolated Analogue Output Isolated 4-20mA
0-10 VDC Output Not Required
Dual Analog Output Single
Digital Input Not Required
Isolated Analogue Input Not Required
  MODULE 2 .
Measurement O2 Purity 2DP
Flowmeter Not Required
Back Pressure Valve, O2 Purity Not Required
External S/S Filter Required w/ Standard Filter
Configurable Alarms Two Alarms
Isolated Analogue Output Isolated 4-20mA
0-10 VDC Output Not Required
Dual Analog Output Single
Digital Input Not Required
Isolated Analogue Input Not Required
  MODULE 3 .
Measurement None
  MODULE 4 .
Measurement None
  AQUAXACT .
AquaXact None
  GENERAL CONFIGURATION.
Power Cord UK
Flow Alarm Not Required
Serial Communications Not Required
Modbus TCP/IP Not Required
Mounting Rack Mount w/ears
Autocal Not Required
Relay Contacts 4 Relay Contacts
Operator Manual English
Extended Chassis Not Required
S/ 81,630.00 81630.0 PEN
XCD Gas Detector Hydrogen
Modelo: SPXCDULNG1
• Honeywell Sensepoint XCD Gas Detector
• Certification: UL/CSA/In metro (+$104.00)
• Sensor Type: Hydrogen; 0-1,000ppm
• Enclosure Material: Epoxy painted aluminum alloy
• Conduit Entry: 3/4 inch NPT
• Communication: None
S/ 4,894.17 4894.17 PEN
Gfx 5 ppm CO2 Spare
Gfx 5 vpm CO2, Spare
Complete GFX sensor for direct replace,ent on 4100 series
Brand: SERVOMEX
S/ 61,313.20 61313.200000000004 PEN