Paddle Type Flow Switch Measuring range/paddle, 2,8-6,0 L/min paddle: 3
Paddle Type Flow Switch
Brand: Kobold (Alemania)
Model: PSR-11103-N-10-R-1
[PSR-11]:
Operating principle: paddle
Mounting position: all directions  
Approvals: w/o
Incl. fitting: brass
Body material: brass     
Max. pressure*: 100 bar   
*only 25 bar at PSR-..32 and PSR-..40  
[103]: Measuring range/paddle, 2,8-6,0 L/min paddle: 3
[N]: Connection, NPT-thread
[10]: Connection, 3/8" (for PSR-xx10...)
[R]: Contact version, N/O
[1]: Connecting cable, PVC-cable 1.5 m (standard)
***************************************************************************
Datasheet: http://www.kobold.com/uploads/files/kfr-gb-flow-1.pdf
S/ 416.08 416.08 PEN
Low Volume Flowmeters, Range: 0,1...1 L/min air. Accuracy ± 5% FS. Total length, 102 mm. Needle valv
Low Volume Flowmeter KFR
Brand: Kobold (Alemania)
Model: KFR-2213-N0 + KFR-PPHW024
[KFR-22]:
Operating principle, variable area
Mounting position, vertical
Flow direction, from bottom
Total length,102 mm
Accuracy, ±5 % FS
Max. temperature, 65 °C
Max. pressure, 6,5 bar
Housing, Acryl
Connection material, St.st.
Connection size,1/8 NPT female on rear
Seal, FPM
[13]: Measuring range, 0,1...1 L/min air
[N0]: Needle valve
[KFR-PPHW024]: Accessories, set hose barbes (2 pcs.), straight for 1/4 hose
******************************************************************************************
Datasheet: http://www.kobold.com/uploads/files/kfr-gb-fl
S/ 739.62 739.62 PEN
Interruptor de flujo calorimétrico, versión compacta
Calorimetric Flowswitch, Compact Version
Brand: Kobold (Alemania)
Model: KAL-K5-3-20-S-PG1
[KAL-K5]:
Operating principle: calorimetric
Mounting position: all directions
Indication: DUO-LED and LED-chain
max. temperature: 80 °C (120 °C for KAL-KH)
max. pressure: 100 bar
Protection class: IP 65
Connection thread: NPT
Version: Standard
[3]: Probe material, st.st. 1.4301
[20]: Connection, 3/4"
[S]: Contact version, N/O
[PG1]: Electron. connection/power supply, M 16x1,5 relay output 110 VAC
S/ 2,032.11 2032.1100000000001 PEN
Medidor de flujo de paletas rotativas (0,3-2,8 L/min)
Rotating Vane Flow Meter
Model: DRH-15-15-N3-C34P
Brand: Kobold (Germany)
DRH-15
Operating principle: Rotating Vane
Mounting position / flow direction: in all directions/ in direction of the arrow
Accuracy: +/-2.5 %
Protection: IP 65
Max. temperature: 80 °C
Max. pressure: 100 bar
Material of housing: 1.4404
Material housing cover: 1.4404
15: Measuring range, 0,3-2,8 L/min
N3: Mech. connection, 3/8 NPT female
C34P: Electronic, Compact electronics, 4-20 mA, 1x PNP
S/ 4,573.17 4573.17 PEN
Medidor de flujo de masa de Coriolis (min. 0-6.000 kg/h - max. 0-60.000 kg/h)
Coriolis-Mass Flow Meter
MODEL: TMU-S-040-206R-A-0-0-A-A-1-0-0+UMC3-B-1-1-A-1-1-KBRAND: KOBOLD
TMU
S: Wetted materials, Stainless steel
040: Meter line size, DN40, ANSI 1½"
Range: min. 0-6.000 kg/h - max. 0-60.000 kg/h
206R: Process connnection, 2" Class 150 RF ASME B16.5-2003
Installation length: 810 mm
A: Containment options, Stainless steel containment 1.4301 (304)
0:  Heating/cooling, without
0:  Heating/cooling, without
A:  Sensor configuration, Integral mount transmitter
Process temperature: -4° to 212°F, -20° to 100°C
A: ApprovaIs, II 1/2G EEx ia IIC T6 - T2
1:  Calibration mass Flow, standard, 3-points
0:  Calibration Density, None
0: Supplementary equipment, None
UMC3: Transmitter IP65,
B: Mounting of transmitter, integratel mount
Conduit port opening: M20 x 1,5
1: Display/Interface board, Integral within transmitter housing, for ambient temperature up to 60°C
1: Power supply, 90-265 VAC, 50/60 Hz
A: Outputs, 
Analog output 1: (0) 4 20mA with HART®
Analog output 2: (0) 4 - 20mA
Pulse output: passive Um=30V DC
Status output: passive Um=30V DC
1:  Approvals, II(1)2G EEx de [ia] IIB/IIC T3-T6 (Type of protection connection area EEx e), for ambient temperature up to 60°C
1:  Type of protection (signal output), EEx ia
K: Design, Kobold
S/ 49,662.12 49662.12 PEN
Thermal Mass Flow Meter for Gas,Measuring range: 0.90-176 Nm³/h for tube DN 25 (1")
Thermal Mass Flow Meter for Gas
Brand: Kobold (Alemania)
Model: KMT-3-16-R-1-Z-L-1-N-Q-4
[KMT-3]
Function principle: Direct thermal flow
Sensor: remote
Flow direction: acc. Mounting
Power supply 18-30 VAC/DC
max. pressure / max. temperature PN 16 / 80 °C
Sensor material st. st./ plastic
[16] Measuring range: 0.90-176 Nm³/h for tube DN 25 (1")
[R] Connection: Ball valve with G-thread
[1] Display, LCD-display
[Z] Cable length sensor/electronic: 10 m with plug M12, 4-pins
[L] Medium, Air
[1] Units, SI units
[N] Physical size, output 1: Standard volume flow (standard Nm³/h)
[Q] Physical size, output 2: Consumption (standard Nm³)
[4] Consumption (standard Nm³): Analogue-output 4-20 mA / totalizer output (standard)
S/ 5,687.67 5687.67 PEN
Coriolis Massflowmeter. Range: min. 0-25.000 kg/h - max. 0-120.000 kg/h. Output 1: 4 - 20mA with HA
Coriolis Massflowmeter
MODEL: TMU-S-040-331B-A-0-0-A-A-10-0+UMC3-B-1-1-A-1-1-K
MARCA: KOBOLD
TMU
S: Wetted materials, Stainless steel
040: Meter line size, DN40, ANSI 1½"
Range: min. 0-6.000 kg/h - max. 0-60.000 kg/h
331B: Process connnection, DN80 PN40 Form B1 DIN EN 1092-1
Installation length: 600 mm
A: Containment options, Stainless steel containment 1.4301 (304)
0:  Heating/cooling, without
0:  Heating/cooling, without
A:  Sensor configuration, Integral mount transmitter
Process temperature: -4° to 212°F, -20° to 100°C
A: ApprovaIs, II 1/2G EEx ia IIC T6 - T2
1:  Calibration mass Flow, standard, 3-points
0:  Calibration Density, None
0: Supplementary equipment, None
UMC3: Transmitter IP65,
B: Mounting of transmitter, integratel mount
Conduit port opening: M20 x 1,5
1: Display/Interface board, Integral within transmitter housing, for ambient temperature up to 60°C
1: Power supply, 90-265 VAC, 50/60 Hz
A: Outputs,
Analog output 1: (0) 4 20mA with HART®
Analog output 2: (0) 4 - 20mA
Pulse output: passive Um=30V DC
Status output: passive Um=30V DC
1:  Approvals, II(1)2G EEx de [ia] IIB/IIC T3-T6 (Type of protection connection area EEx e), for ambient temperature up to 60°C
1:  Type of protection (signal output), EEx ia
K: Design, Kobold
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/tmu_da_en.pd
 
S/ 46,879.59 46879.590000000004 PEN
VARIABLE AREA FLOWMETER
VARIABLE AREA FLOWMETER
Modelo: V31-205R5S-03-E5W-B-F-A-1-X-4-0-2-0-0-0-0-0-K
Marca: Kobold-Heinrichs
V31:
Max. 6 bar
Temp. min. -10 °C, max. 80 °C
Accuracy class VDI/VDE 3513: 2,5% gases
205R5S: Process connection, 1½" 150lbs RF ASME B16.5-2003, length: 500 mm Material, SS
03: Type of float, Material; Stainless steel 1.4571 - with magnet; with guide rod
E5W: Measuring range; 18-180 cuft/min air; 20°C; 14.7 PSI abs.
B: Gasket, EPDM
F: Float-stop, PVDF
A: Union nut, Aluminium lacquered
1: With Shatter protection max. 80°C
X: electrical output; 1 x K 17 A Contact closes below limit; 1 x K 17 B Contact closes above limit
4: Scale, Measuring range-scale (air)
0: Approvals; without
2: Calibration certificate; 5-Points
0: Cleaning according works standard (free of oil and grease); without
0: Pressure / leakage test; without
0: Approvals; without
0: Marking; without
0: Accessories; without
K: Make; Kobold
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/ 7,184.81 7184.81 PEN
Variable Area Flowmeter V31, Measuring range - stainless steel float (guide), 37 a 370 L/min O2
Variable Area Flowmeter
Brand: Kobold – Heinrichs
Model: V31- 60401S-02-D6W-B-F-A-0-0-4-0-0-0-0-0-0-0-K
[V31]: Glass Tube
[60401S]: Description, NPT ¾"(F), Lenght 375 mm, Connection - wetted parts Stainless steel        
[02]: Type of float, Material, Stainless steel 1.4571 – guided with guide road 1.4571
[D6W]: Measuring range - stainless steel float (guide), 37 a 370 L/min O2
[B]: Gasket, EPDM
[F]: Float – stop, PVDF
[A]: Union nut, Aluminium lacquered
[0]: Shatter protection max. 80°C, Without
[0]: Electrical output, Without
[4]: Scale, Measuring range-scale (Oxygen gas)
[0]: Approvals, Without
[0]: Calibration certificate, Without
[0]: Cleaning according works standard (free of oil and grease), Without
[0]: Pressure / leakage test, Without
[0]: Approvals, Without
[0]: Marking, Without
[0]: Accessories, Without
[K]: Make, Kobold
***********************************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/ 2,136.13 2136.13 PEN
Low Volume Flowmeter, Measuring range: 4,0...40 L/h water. Accuracy: class 3. Body material: st.st.
Low Volume Flowmeter
Brand: Kobold (Alemania)
Model: KDF-92-85-N-V-0-00-0
[KDF-92]
Mounting length: 90 mm
Operating principle: variable area
Flow direction: from bottom to top
Body material: st.st.
Glass: Borosilicate
Accuracy: class 3
Max. temperature: without/with contact 100 °C / 70 °C
Max. pressure: PN 16
[85]: Measuring range: 4,0...40 L/h water
[N]: Connection, 1/4 NPT
[V]: Seal, FPM
[0]: Wall mounting kit, w/o
[00]: Contacts measuring range: w/o
[0]: Flow differential pressure regulator, w/o
S/ 1,203.66 1203.66 PEN
VARIABLE AREA FLOWMETER, Measuring range; 2.3 - 23 Nm3/h ,Pressure max. 15 bar Temp. min. -10 °C, ma
VARIABLE AREA FLOWMETER
Modelo: V31-40301S-02-D2W-F-F-A-0-0-4-0-0-0-0-0-0-0-K
Marca: Kobold-Heinrichs
V31:
Pressure max. 15 bar
Temp. min. -10 °C, max. 80 °C
Accuracy: Accuracy: 2,5% Gas
40301S: Process connection, G 3/4"(F), length: 375 mm, 
Connection - wetted parts: Stainless steel
02: Type of float, Material; Stainless steel 1.4571 - guided
guide rod 1.4571: with
D2W: Measuring range; 2.3 - 23 Nm3/h 
F: Gasket, Viton
F: Float-stop, PVDF
A: Union nut, Aluminium lacquered
0: without
0: electrical output; without
4: Scale, Measuring range-scale (Carbon dioxide)
0: Approvals; without
0: Calibration certificate; without
0: Cleaning according works standard (free of oil and grease); without
0: Pressure / leakage test; without
0: Approvals; without
0: Marking; without
0: Accessories; without
K: Make; Kobold
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/ 2,102.69 2102.69 PEN
Flujómetro de área variable
Variable Area Flowmeter DSV
Brand: Kobold (Alemania)
Model: DSV-21-07H-R0-R20
[DSV-21]:
Operating principle, variable area
Mouting position, vertical
Flow direction, from bottom
Fitting material, Brass
Sight glass, Borosilicate
Accuracy, ±4 % FS
Max temperature, 100 °C (metal-float)
Max.pressure, 10 bar
[07H]: Meauring range: 2,5...50 L/min water
[R0]: Contact, 1 N/O
[R20]: Connection measuring range, 
G 3/4 female (betw. 10 and 50 L/min)
S/ 1,935.52 1935.52 PEN
Variable Area Flowmeter
Variable Area Flowmeter DSV
Brand: Kobold (Alemania)
Model: DSV-21-06H-R0-N20
[DSV-21]:
Operating principle, variable area
Mouting position, vertical
Flow direction, from bottom
Fitting material, Brass
Sight glass, Borosilicate
Accuracy, ±4 % FS
Max temperature, 70 °C (plastic-float)
Max.pressure, 10 bar
[06H]: Meauring range: 2-25 L/min*
*plastic float 70°C
[R0]: Contact, 1 N/O
[N20]: Connection measuring range, 3/4 NPT fem. (betw. 10 and 50 L/min)
***************************************************************************************************
Datasheet: http://www.koboldmessring.com/fileadmin/koboldfiles/pdf/gb/s2gb_dsv.pdf
S/ 1,887.22 1887.22 PEN
Low Volume Flowmeters, Range: 0,05...0,5 L/min air. Accuracy ± 5% FS. Total length, 102 mm. Needle v
Low Volume Flowmeter KFR
Brand: Kobold (Alemania)
Model: KFR-2212-N0 + KFR-PPHW024
[KFR-22]:
Operating principle, variable area
Mounting position, vertical
Flow direction, from bottom
Total length,102 mm
Accuracy, ±5 % FS
Max. temperature, 65 °C
Max. pressure, 6,5 bar
Housing, Acryl
Connection material, St.st.
Connection size,1/8 NPT female on rear
Seal, FPM
[12]: Measuring range, 0,05...0,5 L/min air
[N0]: Needle valve
[KFR-PPHW024]: Accessories, set hose barbes (2 pcs.), straight for 1/4 hose
******************************************************************************************
Datasheet: http://www.kobold.com/uploads/files/kfr-gb-flow-1.pdf
S/ 739.62 739.62 PEN
VARIABLE AREA FLOWMETER

VARIABLE AREA FLOWMETER
Modelo: V31-40301S-01-D3W-F-F-A-0-0-4-0-0-0-0-0-0-0-K
Marca: Kobold-Heinrichs
V31:
Pressure max. 15 bar
Temp. min. -10 °C, max. 80 °C
Accuracy: Accuracy: 2,5% Gas
40301S: Process connection, G 3/4"(F), length: 375 mm,
Connection - wetted parts: Stainless steel
01: Type of float, Material; Stainless steel 1.4571 - without guide rod
D3W: Measuring range; 2 - 20 Nm3/h
F: Gasket, Viton
F: Float-stop, PVDF
A: Union nut, Aluminium lacquered
0: without
0: electrical output; without
4: Scale, Measuring range-scale (Carbon dioxide)
0: Approvals; without
0: Calibration certificate; without
0: Cleaning according works standard (free of oil and grease); without
0: Pressure / leakage test; without
0: Approvals; without
0: Marking; without
0: Accessories; without
K: Make; Kobold
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/ 1,961.52 1961.52 PEN
Rotating Vane Flow Meter. Range: 2-40 L/min water. Connection: 3/4 NPT male. Frequency output, plug
MODELO: DRS-9-3-50-N5-F300-0
Rotating Vane Flow Meter
DESCRIPTION:
DRS-9:
Operating principle, rotating vane
Mounting position, all directions
Flow direction, in direction of the arrow
Max. Temperature, 80°C
Max. Pressure, 16 bar
Accuracy, +/-1, 5%
Protection, IP65
3: Material; plastic
50: Measuring range: 2-40 L/min. water
N5: Connection; 3/4 NPT male
F300: Evaluating Electronic; Frequency output, plug M12x1, PNP
0: Options; w/o
Datasheet:
http://www.kobold.com/uploads/files/s4gb_drs.pdf
S/ 687.28 687.28 PEN
Rotating Vane Flow Meter,Max. Temperature, 80°C Max. Pressure, 16 bar
MODELO: DRS-9-3-50-G4-F500-0
Rotating Vane Flow Meter
DESCRIPTION:
DRS-9:
Operating principle, rotating vane
Mounting position, all directions
Flow direction, in direction of the arrow
Max. Temperature, 80°C
Max. Pressure, 16 bar
Accuracy, +/-1, 5%
Protection, IP65
3: Material; plastic
50: Measuring range: 2-40 L/min. water 
G4: Connection; G 1/2 female/ male
F500: Evaluating Electronic; Frequency output, 2m PVC-cable, PNP
0: Options; w/o
Datasheet:
http://www.kobold.com/uploads/files/s4gb_drs.pdf
S/ 687.28 687.28 PEN
Flujómetro de rueda de turbina (1.2 - 20.0 m3/h water)
Turbine Flowmeter TUR
Brand: Kobold (Alemania)
Model: TUR-1050-N
[TUR-10]:
Operating: Turbine Wheel
Mounting position: horizontal / vertical
Flow direction: in direction of the arrow
Max. operating temperature: 60 °C (PVC version)
Max. operating pressure: PN 10
Measuring accuracy: ±1% of f. s.
Protection type: IP 65
Frequency Pulses/Liter: 14.30
Frequency range: 4.8 - 79.40 Hz 
Model designation wetted parts: PVC
[50]: Connection / Measuring range:
Connection PVC flange NW: 50
Measuring range: 1.2 - 20.0 m3/h water
[N]: Electronic, Pulse output NPN (24 VDC, 3-wire)
S/ 4,327.98 4327.9800000000005 PEN
VARIABLE AREA FLOWMETER
VARIABLE AREA FLOWMETER
Modelo: V31-60301S-01-C7W-F-F-A-0-0-4-0-2-0-0-0-0-0-K
Marca: Kobold-Heinrichs
V31:
Pressure max. 15 bar
Temp. min. -10 °C, max. 80 °C
Accuracy: Accuracy: 1,6% Liquid
60301S: Process connection, NPT ½"(F), length: 375 mm,
Connection - wetted parts: Stainless steel
01: Type of float, Material; Stainless steel 1.4571 - without guide rod
C7W: Measuring range; 0.8 - 8.0 L/min
F: Gasket, Viton
F: Float-stop, PVDF
A: Union nut, Aluminium lacquered
0: without
0: electrical output; without
4: Scale, Measuring range-scale (Sodium sulfate)
0: Approvals; without
2: Calibration certificate; 5-Points
0: Cleaning according works standard (free of oil and grease); without
0: Pressure / leakage test; without
0: Approvals; without
0: Marking; without
0: Accessories; without
K: Make; Kobold
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/ 2,050.68 2050.68 PEN
Baffle Plate System Flow Transmitter for Liquids, dn100, SS
Baffle Plate System Flow Transmitter for Liquids
Brand: Kobold (Alemania)
Model: DWD-36-W80-3-L-T-0
[DWD-36]:
Operating principle: Baffle plate system
Indication: LCD-display
Flow direction: in directon of the arrow
Output: 2 switching contacts + 4-20 mA
Max. temperature: 120 °C
Connection: weld on
Material (T-piece): st. st.
[W1H]: Connection size, for pipe size DN 100
[3]: Power supply, 24 VDC
[L]: Flow direction, from left to right
[T]: Mounting position, on top of the lead
[0]: Option, w/o further options
S/ 5,349.60 5349.6 PEN