Calorimetric Flowswitch Compact Version. Sensor Length (C) = 50 mm. Connection, 3/2" NPT. relay outp
Calorimetric Flowswitch, Compact Version
Brand: Kobold (Alemania)
Model: KAL-K8-4-20-S-PG0
[KAL-K8]:
Operating principle calorimetric
Mounting position all directions
Indication DUO-LED and LED-chain
max. temperature 80 °C (120 °C for KAL-KH)
max. pressure 100 bar
Protection class IP 65
Connection thread NPT
[4]: Probe material, st.st. 1.4571
Version, Sensor Length (C) = 50 mm
[20]: Connection, 3/4"NPT
[S]: Contact version, N/O
[PG0]: Electron. connection/power supply, M 16x1,5 relay output 230 VAC
S/
2,804.83
2804.83
PEN
Flow Transmitter with Weld-on Connection,Flow Range (GPM Water): 31.7....396,Analog Output: 4 ... 20
Flow Transmitter with Weld-on Connection
Brand: Kobold (Usa)
Model: DWD-75-3-LT-7
Flow Range (GPM Water): 31.7....396
Accuracy: ± 1.5 % f.s.
Nominal Pipe diameter: W80=3"
Direction of Flow: Left to Right, Indicator Above Pipe
Analog Output: 4 ... 20 mA or 0 ... 10 V, User Selectable
Power Supply: 24 VDC
Protection Type: IP 65
Option: RS-232C Serial Interface
***********************************************************************************
Datasheet: http://koboldusa.com/sites/default/files/product_files/Paddle-Bellows-Flowmeter-Switch-DWD_0.pdf
S/
8,897.43
8897.43
PEN
Medidor/interruptor de flujo de viscosidad compensada (0,2...1,2 L/min oil )
Viscosity Compensated Flowmeter /-switch
Brand: Kobold (Alemania)
Model: VKM-31-03-R0-R08-0-T
[VKM-31]:
Operating principle variable area
Mounting position all directions
Flow direction in direction of the arrow
Body material Brass
Seal: NBR
Switch point: adjustable
Accuracy: ±4 % FS (at 105 mm²/s)
Max. temperature: 100 °C
Max. pressure: 250 bar
Viscosity range: 1...540 mm²/s
[03]: Measuring range 0,2...1,2 L/min oil
[R0]: Contact: 1 N/O
[R08]: Connection: G 1/4 female
* for <= 9 L/min
[0]: Option special connection, w/o
[T]: Flow direction: from top
S/
2,726.81
2726.81
PEN
Magnetic Inductive Flow Meter with flange,Max. medium temperature: 150°C,Connection flange ASME 16.
Magnetic Inductive Flow Meter with flange
Brand: Kobold (Alemania)
Model: DMH-2-L3H-T-4-4-A-1-6
[DMH-2]:
Mounting position, all directions
Display / Protection class, LCD Display / IP 67
Output, Analogue, frequency, connection and status output
Max. medium temperature: 150°C
Connection: St. steel
Coating: PTFE
[L3H]: Connection flange ASME 16.5, 12" 150 lbs max. 0..2682 m³/h
[T] Lining: PTFE
[4] Electrodes material: Titan
[4] Grounding Electrodes material: Titan
[A] Version/cable length: compact version, 1/2 NPT connection
[1] Electronic: UMF2(B)-Electronic without HART®
[6] Power supply/Cable entries: 115 VAC 1/2 NPT
*******************************************************
Datasheet: http://www.kobold.com/uploads/files/dmh-gb-flow-1.pdf
S/
47,336.53
47336.53
PEN
Medidor de flujo magnético inductivo con brida (0..1896 m³/h)
Magnetic Inductive Flow Meter with flange
Brand: Kobold (Alemania)
Model: DMH-2-L2F-T-4-4-A-1-6
[DMH-2]:
Mounting position, all directions
Display / Protection class, LCD Display / IP 67
Output, Analogue, frequency, connection and status output
Max. medium temperature: 150°C
Connection: St. steel
Coating: PTFE
[L2F]: Connection flange ASME 16.5, 10" 150 lbs max. 0..1896 m³/h
[T] Lining: PTFE
[4] Electrodes material: Titan
[4] Grounding Electrodes material: Titan
[A] Version/cable length: compact version, 1/2 NPT connection
[1] Electronic: UMF2(B)-Electronic without HART®
[6] Power supply/Cable entries: 115 VAC 1/2 NPT
S/
41,210.50
41210.5
PEN
Magnetic Inductive Flow Meter with flange, . 0..1188 m³/h , 8 pulg
Magnetic Inductive Flow Meter with flange
Brand: Kobold (Alemania)
Model: DMH-2-L2H-T-4-4-A-1-6
[DMH-2]:
Mounting position, all directions
Display / Protection class, LCD Display / IP 67
Output, Analogue, frequency, connection and status output
Max. medium temperature: 150°C
Connection: St. steel
Coating: PTFE
[L2H]: Connection flange ASME 16.5, 8" 150 lbs max. 0..1188 m³/h
[T] Lining: PTFE
[4] Electrodes material: Titan
[4] Grounding Electrodes material: Titan
[A] Version/cable length: compact version, 1/2 NPT connection
[1] Electronic: UMF2(B)-Electronic without HART®
[6] Power supply/Cable entries: 115 VAC 1/2 NPT
S/
36,923.39
36923.39
PEN
Paddle Type Flow Switch-PSR, Measuring range/paddle, 7.7-13.4 L/min paddle: 6
Paddle Type Flow Switch
Brand: Kobold (Alemania)
Model: PSR-12-206-N-20-R-1
[PSR-12]:
Operating principle: paddle
Mounting position: all directions
Incl. fitting: st.st.
Body material: st.st.
Max. pressure*: 250 bar
*only 25 bar at PSR-..32 and PSR-..40
[206]: Measuring range/paddle, 7.7-13.4 L/min paddle: 6
[N]: Connection, NPT-thread
[20]: Connection, 3/4" (for PSR-xx20...)
[R]: Contact version, N/O
[1]: Connecting cable, PVC-cable 1.5 m (standard)
S/
1,460.00
1460.0
PEN
Medidor/contador de flujo de engranajes ovalados (10-150 L/min; 1 NPT)
Oval Gear Flow Meter/Counter
Brand: Kobold (Alemania)
Model: DON-2-25H-N6-1-Z3-N-0-Y
[DON-2]:
Operating principle Gear Wheel
Mounting position horizontal / vertical
Flow direction in direction of the arrow
max. temperature 120 °C*
max. pressure 16…100 bar
Accuracy ±0,2 % …1 % of reading
Housing material st. steel
Rotor material st. steel
[25H]: Measuring range, 10-150 L/min
[N6]: Mech. Connection, 1 NPT
[1]: Seal, FKM up to DON-x25
[Z3]: Electronic, dual LCD totaliser/rate, outputs: pulse, analogue
[N]: Cable entry, 1/2 NPT
[0]: Options (please specify in clear text), without
[Y]: Options, no include battery
S/
6,987.92
6987.92
PEN
Oval Gear Flow Meter/Counter
l Gear Flow Meter/Counter
Brand: Kobold (Alemania)
Model: DON-2-20H-N4-1-Z3-N-0
[DON-2]:
Operating principle Gear Wheel
Mounting position horizontal / vertical
Flow direction in direction of the arrow
max. temperature 120 °C*
max. pressure 16…100 bar
Accuracy ±0,2 % …1 % of reading
Housing material st. steel
Rotor material st. steel
[20H]: Measuring range, 1 - 40 L/min
[N4]: Mech. Connection, 1/2 NPT
[1]: Seal, FKM up to DON-x25
[Z3]: Electronic, dual LCD totaliser/rate, outputs: pulse, analogue
[N]: Cable entry, 1/2 NPT
[0]: Options (please specify in clear text), without
*not include battery
S/
5,765.68
5765.68
PEN
Medidor de flujo de área variable totalmente metálico (Rango [l/h] : 2500 - 25000)
All-Metal Variable Area Flowmeter BGN
Brand: Kobold – Heinrichs (Alemania)
Model: BGN-S50-6870-U000-0-S20-X-K
Function
Measuring principle: Float-element
Operating conditions
Fitting position: vertical
Flow direction: bottom to top
Performance characteristics
Measured error (local): +/- 1,6% of full scale
Process conditions
Range [l/h] : 2500 - 25000
Fluid: Water
Density [kg/m³] : 1000
Viscosity [mPas] : 1
Process temperature [°C] : 20
Process pressure [pe bar] : 6
Mechanical construction
Material-body : SS 1.4571 / 1.4404
Material-process connection : SS 1.4301 / 1.4404
Material-float: SS 1.4571 / 1.4404
Material-measuring ring: SS 1.4571 / 1.4404
Type-float: KU
Measuring ring: 50 mm i. d.
Nominal-pressure: 16 bar
Process connection - DIN 32676
upstream (DN1): DN65 - clamp nozzle
downstream (DN2): DN65 - clamp nozzle
Flange face: --
Overall length [mm] : 250
Accessory: without
Armature and process connection electropolishing RA <0,8 µm
S/
26,188.89
26188.89
PEN
Variable Area Flowmeter, 100 L/h , G 1/2
Variable Area Flowmeter/-switch Glass Cone with Thread Connection
Brand: Kobold (Alemania)
Model: URM-55-24H-I4-0
[URM-55]
Mounting position: vertical, flow direction from bottom
Accuracy: Class 4
Max. temperature: 100°C
Max. pressure: 6 bar...16 bar depend see data sheet
Material: connection, float / seal/ ring, 1.4404 / FPM / PTFE
[24H]: Range Full Scale* water, 100 L/h
[I4]: Connection female: G 1/2
[0]: Contacts: w/o, for meas. range: all
S/
1,634.60
1634.6000000000001
PEN
Micro Variable Area Flowmeter KDS
Micro Variable Area Flowmeter KDS
Brand: Heinrichs - Kobold
Model: KDS-K-I-P-U-0-E-0-0
[KDS]:
All-metal design
Range (0,1-1 l/h - 20-200 l/h H2O)
Connection ¼" NPT (f)
Temp. min. -40 °C, max. 130 °C
[K]: Variable Area Flowmeter, rear connection,
overall length 90 mm, max. 40 bar, measuring accuracy 3% of range
[I]: Range: H2O: 10 - 100 l/h / 13 - 120 l/h Alcohol
Air 1,013 bar abs., 20°C, Air 300-3000 Nl/h
[P]: Sealing: PTFE
[U]: Valve: bottom not with el. output "E" (not for KDS-S)
[0]: Certificates: without
[E]: Scale: Measuring Range-Scale (Alcohol)
Approval: IIC 2GD c IIC (BVS 03 ATEX H-B 113)
[0]: Switches: without
Processtemperature -40°C - +130°C
[0]: Accessories: without
*****************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/kds_bgk_db_en.pdf
S/
2,611.65
2611.65
PEN
Micro Variable Area Flowmeter KDS, Range (0,1-1 l/h - 20-200 l/h H2O)
Micro Variable Area Flowmeter KDS
Brand: Heinrichs - Kobold
Model: KDS-K-I-P-U-0-E-E-0
[KDS]:
All-metal design
Range (0,1-1 l/h - 20-200 l/h H2O)
Connection ¼" NPT (f)
Temp. min. -40 °C, max. 130 °C
[K]: Variable Area Flowmeter, rear connection,
overall length 90 mm, max. 40 bar, measuring accuracy 3% of range
[I]: Range: H2O: 10 - 100 l/h / 13 - 120 l/h Alcohol
Air 1,013 bar abs., 20°C, Air 300-3000 Nl/h
[P]: Sealing: PTFE
[U]: Valve: bottom not with el. output "E" (not for KDS-S)
[0]: Certificates: without
[E]: Scale: Measuring Range-Scale (Alcohol)
Approval: IIC 2GD c IIC (BVS 03 ATEX H-B 113)
[E]: Switches: Transmitter 4-20mA w/o HART
Connection: M12 plug
Processtemperature -25C - +100°C
[0]: Accessories: without
*****************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/kds_bgk_db_en.pdf
S/
3,774.44
3774.44
PEN
Paddle Type Flow Switch. Measuring range/paddle, 2.5-6.4 L/min paddle: 3. Mounting position all dire
Paddle Type Flow Switch
Brand: Kobold (Alemania)
Model: PSR-11-153-R-15-U-1
[PSR-11]:
Operating principle paddle
Mounting position all directions
Approvals ---
incl. fitting brass
Body material brass
max. pressure 100 bar
[153]: Measuring range/paddle, 2.5-6.4 L/min paddle: 3
[R]: Connection, G-thread
[15]: Connection, 1/2" (for PSR-xx15..)
[U]: Contact version, SPDT
[1]: Connecting cable, PVC-cable 1.5 m (standard)
S/
453.23
453.23
PEN
Caudalímetro de Coriolis (min. 0-3.000 kg/h - max. 0-30.000 kg/h)
Coriolis Massflowmeter
Brand: Kobold - Heinrichs
Model: TME-S-95-206R-0-L-1-0-1-0-H / UMC4-B-1-1-A-0-0
[TME]:
[S]: Wetted materials, Stainless Steel
[95]: Range: min. 0-3.000 kg/h - max. 0-30.000 kg/h (Sensor TME025)
[206R]: 2" Class 150 RF ASME B16.5-2003
Face to face dimension 500mm
[0]: Heating Cooling, without
[L]: Flow direction, Left to right
[1]: Sensor configuration, Integral mount transmitter
[0]: Approvals, without approval
[1]: Certificate, Certificate of compliance with the order, 2.1
[0]: Supplementary equipment, without
[H]: Design, Heinrichs
**********************************************************************************************
[UMC4] Transmitter
[B] Mounting, Integral mount, Conduit port opening M20 x 1,5
[1] Display/Interface board, Integral within transmitter housing, for ambient temperature up to 60°C
[1] Power supply, 90 - 265V AC, 50/60Hz
[A] Outputs,
Analog output 1: 4 - 20mA with HART®
Analog output 2: 4 - 20mA
Pulse output: passive Um=30V DC
Status output: passive Um=30V DC
[0] Approvals, none
[0] Type of protection (signal output), none
S/
18,396.68
18396.68
PEN
Flowindicator with Threaded Connection Max. pressure 16 bar (Option 25 or 40 bar)
Flowindicator with Threaded Connection
Brand: Kobold (Alemania)
Model: DAK-1-2-01H-R-08
[DAK-1]:
Operating principle Flap
Mounting position horizontal
Flow direction in direction of the arrow
Max. Temperature 150 °C (Option B: 280 °C)
Max. pressure 16 bar (Option 25 or 40 bar)
[2]: Housing, St.st.
[01H]: Nom. Diameter, 1/4"
[R]: Thread, G-thread female
[08]: Connection, 1/4"
S/
2,385.03
2385.03
PEN
Interruptor de paleta de polisulfona
Polysulfone Paddle Switch
Model: PPS-3203
Brand: Kobold (USA)
Switch Housing: Polysulfone
Process Connection: 1" NPT
Max. Temperature: 105 °C
Max. Pressure: 10 Bar
Mounting Orientation: Paddle: Vertical
Output: Contact SPDT
S/
594.40
594.4
PEN
Medidor de flujo másico térmico para gas (2.26-452 Nm³/h)
Thermal Mass Flow Meter for Gas
Brand: Kobold (Alemania)
Model: KMT-2-18-N-1-0-C-1-N-Q-3
[KMT-2]:
Function principle Direct thermal flow
Sensor fix mounted
Flow direction left to right
Power supply 18-30 V AC/DC
max. pressure / max. temperature PN 16 / 80 °C
Sensor material st. st./ plastic
[18]: Measuring range, 2.26-452 Nm³/h for tube DN 40 (11/2")
[N]: Connection, Ball valve with NPT-Thread 1 1/2"
[1]: Display, LCD-display
[0]: Cable length sensor/electronik, w/o
[C]: Medium, CO2
[1]: Units, SI Units
[N]: Physical size, output 1, Standard volume flow (standard Nm³/h)
[Q]: Physical size,output 2, Consumption (standard Nm³)
[3]: Output 1/ Output 2, Analogue-output 0-10 V / totalizer output
S/
6,594.13
6594.13
PEN
Variable Area Flowmeter, Measuring range - stainless steel float (Range [US GPM] : 3 - 30, Fluid: So
Variable Area Flowmeter
Brand: Kobold – Heinrichs (Alemania)
Model: V31-60701F-06-E5W-B-F-A-0-0-4-0-0-0-0-0-0-0-K
[V31]:
[60701F]:
Thread: NPT 1½"(F) Verschraubung, Length, 375 mm, connection - wetted parts PVDF
[06]: Type of float, Material, PVDF - weighted, guide rod 1.4571: without
[E5W]: Measuring range - stainless steel float (Range [US GPM] : 3 - 30, Fluid: Sodium Bisulfite)
[B]: Gasket, EPDM
[F]: Float Stop, PVDF
[A]: Union nut, Aluminium lacquered
[0]: Shatter protection max. 80°C, without
[0]: Electrical output, without
[4]: Scale, Measuring range-scale (Medium)
[0]: Approvals, without
[0]: Calibration certificate, without
[0]: Cleaning according works standard (free of oil and grease), without
[0]: Pressure / leakage test, without
[0]: Approvals, without
[0]: Marking, without
[0]: Accessories, without
[K]: Make, Kobold
********************************************************************************************************************
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/v31_db_en.pdf
S/
4,903.80
4903.8
PEN
Variable Area Flowmeter/-switch,Max. temperature: 100 °C (metal-float) Max. pressure: 10 bar
Variable Area Flowmeter/-switch
Brand: Kobold (Alemania)
Model: DSV-12-06H-00-R20
[DSV-12]:
Operating principle: variable area
Mounting position: vertical
Flow direction: from bottom
Fitting material: st.st.
Sight glass: Borosilicate
Accuracy: ±4 % FS
Max. temperature: 100 °C (metal-float)
Max. pressure: 10 bar
[06H]: Measuring range: 2...25 L/min water
[00]: Contact w/o
[R20]: Connection measuring range: G 3/4 female (betw. 10 and 50 L/min)
S/
2,671.09
2671.09