DETECTOR DE GAS CLORO SCOTT MERIDIAN, 3/4 NPT, 0 - 30 ppm, Nema 4X IP 66
DETECTOR DE GAS CLORO ,MARCA: SCOTT,MODELO: MERIDIAN,INCLUYE: ,**096-3533-01 ,ALUMINUM ENCLOSURE, STANDARD DISPLAY,,PLASTIC END CAP,Protección: Nema 4X IP 66,Tipo de conexión: 3/4 NPT,**096-3473-20,MERIDIAN CHLORINE SENSOR ,CL2 ROCK SOLID, HIGH RELATIVE HUMIDITY,Tipo de sensor: Electroquimico Rock Solid,Gas: Cloro (CL2),Rango de Sensor: 0 - 30 ppm,**096-3441,DELUGE GUARD,Aprobaciones:,IECEx, CCSAUS, ATEX, INMETRO, EURASIAN,CUSTOMS UNION, CHINA EX, CCCF, RCM,,FCC, INDUSTRY CANADA, CE, ANATEL,,MARINE DIRECTIVE – SHIP’S WHEEL, ABS SIL-2,(certificación por terceros de TÜV-Rheinland),Clasificación de Area:,Clase I Div. 1 Grupo ABCD, Clase II Div. 1,Grupo EFG, Clase III,Grupo de equipos I/II, Zona 0/20 y Zona 1/21,,IIC
S/ 0.00 0.0 PEN
MERIDIAN CHLORINE SENSOR- Cl2 ROCK SOLID, HIGH RELATIVE HUMIDITY
MERIDIAN CHLORINE SENSOR- Cl2 ROCK SOLID, HIGH RELATIVE HUMIDITY
For “MERIDIAN UNIVERSAL GAS DETECTOR”


S/ 0.00 0.0 PEN
Detector de Gas Portatil c/sonda, bomba y manguera, CO:0 - 999 ppm, H2S:0 - 500 ppm, O2:0 - 25% vol,
PROTEGE PRO-112212 (O2/LEL/CO/H2S)
DETECTOR MULTIGÁS PORTÁTIL
Marca:SCOTT SAFETY
Modelo : PROTEGE,O2/LEL/CO/H2S
(Incluye monitor de gas,cargador,herramienta torx,
manual,CD con software para PC,cable USB y adaptador de calibración.
Rango de Sensores:
CO:0 - 999 ppm,
H2S:0 - 500 ppm,
O2:0 - 25% vol,
Combustible:0 - 80% LEL.
Aprobaciones:(UL):Clase
1,Div. 1 Grupos A,B,C,D T4,CSA:Clase 1,Div. 1
Grupos A,B,C,D T4,ATEX:Ex d ia IIC T4,Australia
a:Ex d ia IIC,T4,Homologación IP 67:cumplimien
to probado por terceros,EMC:Directiva EMC(2004/
108/EC) Marca CE
HOJA TECNICA(BAJAR DE ESTE LINK)
http://www.box.com/s/j0kjdogo6ej8o86bb51v
Pump kit (pump,10 ft,clear sample tubing,clear ,probe w/hydrophobic & particulate filters)
S/ 0.00 0.0 PEN
704000
• Zr704 Zirconia O2 Cell, Low-Activity
S/ 0.00 0.0 PEN
S/ 0.00 0.0 PEN
CC02
Engineers Bag (for 3 cylinders)
S/ 0.00 0.0 PEN
Regulador de Gas
•Regulators for Non -Refillable cylinders
•On/Off Knob with cylinder pressure gauge
•Attachable cylinders: 34DA, 60DA, 103DS,112DA
•Valve: C10
•Flow rate: 1.0 l/min
•Material. Stainless Steel
S/ 1,237.15 1237.15 PEN
Detector Autónomo de Combinación de Gases., CO
FIRST ALERT - ALARM
Explosive Gas & Carbon Monoxide Alarm
Product Dimensions (LxWxH):3.1 x 1.8 x 5.6 in.
Product Weight: .9 lbs.
S/ 544.20 544.2 PEN
6064-55-E-5-2-2-2-1-0-N-Ndetector de hcn, 0-100 PPM, 3/4 NPT
FREEDOM 6000 ECHEM DETECTORS,GAS MODEL: HCN STD RH (25, 100 PPM range only) ,GAS RANGES: 0-100 PPM ,SENSOR TECHNOLOGY: E CHEM ,ALUMINUM 3/4 NPT (CONDENSING HUMIDITY SENSOR HEAD),APPROVAL: cCSAus CLASS 1, DIV 2 ,ACCESSORIES: RAIN SHIELD ,OUTPUT: MODBUS/RELAYS (3) ,CONNECTION: INTEGRAL 


S/ 0.00 0.0 PEN
ELECTROLYTE_BLUEPotassium Hydroxide Solution
Potassium Hydroxide Solution, ,UN 1814,UN 1814 Packing group II Class 8,Limited quantity Y840,100ml
S/ 0.00 0.0 PEN
Replenishmnt solution 100ml purified H2O
Replenishmnt solution ,100ml purified H2O
S/ 0.00 0.0 PEN
analizador ambiental de oxigeno
Paracube Micro O2 Assembly,Paracube Micro O2 Sensor with Display,Servomex,(Codigo antiguo: UK31717SYS01)
S/ 6,936.74 6936.74 PEN
E4400-3DE4400-3D
E4400 Gas Analyzer including:,O2 Sensor               0 to 25 %,CO Sensor              0 to 8000 ppm*, *With Auto-Range up to 50,000 ppm,NO/NOx Sensor     0 to 4000 ppm,CO2 Calculated       0 to 99.9 %,Flue Gas & Air Temperature Measurement,Draft & Differential Pressure Measurement,Efficiency, Losses, & Excess Air Calculations,300mm Probe, 800oC max, with 3m Dual Hose,External Water Trap with Filter Cartridge,Rechargeable Li Ion Batteries & AC Charger,Internal Memory, 900 Tests,Internal Impact Printer (Non-Thermal),Rubber Holster with Magnetic Support,PC Software Package with USB Cable,ABS Hard Plastic Carrying Case,Operating Instructions & Calibration Cert
 
S/ 0.00 0.0 PEN
E4400 Gas Analyzer including O2 Sensor, 0 to 25 %,CO Sensor ,0 to 8000 ppm
E4400 Gas Analyzer including:,O2 Sensor               0 to 25 %,CO Sensor              0 to 8000 ppm*, *With Auto-Range up to 50,000 ppm,NO/NOx Sensor     0 to 4000 ppm,SO2 Sensor             0 to 4000 ppm,CO2 Calculated       0 to 99.9 %,Flue Gas & Air Temperature Measurement,Draft & Differential Pressure Measurement,Efficiency, Losses, & Excess Air Calculations,300mm Probe, 800oC max, with 3m Dual Hose,External Water Trap with Filter Cartridge,Rechargeable Li Ion Batteries & AC Charger,Internal Memory, 900 Tests,Internal Impact Printer (Non-Thermal),Rubber Holster with Magnetic Support,PC Software Package with USB Cable,ABS Hard Plastic Carrying Case,Operating Instructions & Calibration Cert.
S/ 0.00 0.0 PEN
Insertion Tube Flange STL Compact,SPECIALIZED FLANGE 15mm INSERTION TUBE
Insertion Tube Flange STL Compact,SPECIALIZED FLANGE 15mm INSERTION TUBE,CONTINUOUS N2 PURGE AND BACK-UP STEAM PURGE,FLANGE DEFAULT SIZE=ANSI 2” 150 LB
S/ 0.00 0.0 PEN
Model 2900 Utility Panel
Model 2900 Utility Panel,THIS IS AN OPTION,This purge panel includes gas pressure regulators,and flowmeters to control the instrument and,flange purge flows. This panel facilitate handling,of instrument air at the installation site
S/ 0.00 0.0 PEN
ANALIZADOR LASER 2900 NH3 AMONIACO
SERVOTOUGH Laser Compact,With the following configuration,Area Classification Safe Area,Supply Voltage 110 - 220Vac 50/60Hz,Maximum Flange Temperature Not Required,Maximum Ambient Temperature <60°C,Measurement 14203 NH3 Compact Monitor,Measuring Range 0 - 15,Measurement Units % vol,Dual Measurement Not Required,Gas Component 1 N2,Stream Comp 1 Normal Range 54%,Gas Component 2 O2,Stream Comp 2 Normal Range 13%,Gas Component 3 H2O,Stream Comp 3 Normal Range 22%,Gas Component 4 NH3,Stream Comp 4 Normal Range 7%,Stream Comp 4 Low Range 5%,Stream Comp 4 High Range 15%,Process Dust (mg/m3) 0,Stream Temperature (ºC) 78,TU/RU Connecting Cable 5-15m 5,21417 TU/PSU Cable (L5) 3,TU Optical Path Length L1 (mm) 150,Process Optical Path L2 (mm)305,RU Optical Path Length L3 (mm) 150,Process Pressure Units Bar,Process Pressure 1.5,Optical Window Purging Instrument Air,Mounting Flange ANSI 2"/150lbs,Transmission Output 13475 Addnl 4-20mA - Trans O/P,Ethernet Output 15021 Ethernet/Modbus TCP Conn,TU Purge Fitting Size 14513
S/ 3.63 3.63 PEN
Analizador de Oxigeno Servomex Transfill

SERVOFLEX Mini Transfill Analizador Portatil
Analizador de Pureza de Oxigeno
Medidor de Puerza de Oxigeno
Rango: 0 a 100%
preccision:    +-0.1%
T90(tiempo de respuesta)   menor a 10 segundos
Con la siguiente configuracion
Suministro de energía 110V, 220VAC(Con Adaptador Universal)
Medición de oxígeno,
precisión estándar 0,1%
Rango: 0 a 100%
Sistema de muestreo AFCD, •
Nota. No Incluye Bateria
S/ 25,033.20 25033.2 PEN
Detector PROTEGE O2/LEL/H2S
-Kit para espacios confinados,O2/LEL/H2S
-DETECTOR MULTIGÁS PORTÁTIL
-Marca:SCOTT SAFETY,
-Kit de monitor PROTEGE,O2/LEL/H2S(Incluye mo,nitor de gas,cargador,herramienta torx,manual,,CD con software para PC,cable USB y adaptador de calibración
-Sensores:,H2S:0 a 500 ppm,O2:0,% a 25%,Combustible:0% a 80% límite explosivo(L,EL)  ,-Aprobaciones:UL:Clase 1,Div. 1 Grupos ,A,B,C,D T4,CSA:Clase 1,Div. 1 Grupos A,B,C,D T,4,ATEX:Ex d ia IIC T4,Australia:Ex d ia IIC,T,4,Homologación IP 67:cumplimiento probado por te,rceros,EMC:Directiva EMC(2004/108/EC) Marca CE ,Nota.- Incluye Bomba,Sonda,Manguera y Kit, de calibracion en una maleta plastica revestida d,e espuma protectora  ,HOJA TECNICA(BAJAR DE ESTE, LINK)  ,http://www.box.com/s/j0kjdogo6ej8o86,bb51v
S/ 0.00 0.0 PEN
Detector Gas Portatil Oxigeno Monoxido LEL
-DETECTOR MULTIGÁS PORTÁTIL  ,-Marca:SCOTT SAF,ETY  ,-Kit de monitor PROTEGE,O2/LEL/CO(Incluye, monitor de gas,cargador,herramienta torx,manua,l,CD con software para PC,cable USB y adaptador d,e calibración.  ,-Sensores:CO:0 a 999 ppm,O2,:0% a 25%,Combustible:0% a 80% límite explosivo,-Aprobaciones:UL:Clase 1,Div. 1 Grupos A,B,,C,D T4,CSA:Clase 1,Div. 1 Grupos A,B,C,D T4,,ATEX:Ex d ia IIC T4,Australia:Ex d ia IIC,T4,,Homologación IP 67:cumplimiento probado por terce,ros,EMC:Directiva EMC(2004/108/EC) Marca CE
S/ 0.00 0.0 PEN