Valve Inlet: C-10 (70-SS-1 LPM)
70-SS-1 LPM

• Brand Intrial 

• Valve Inlet: C-10

• Flow Rate: 1 LPM FIXED

• Gauge PSI: 1500 PSI / 10000 kpa

• Material: Stainless Steel

• Fits Cylinder: 34L Aluminum, 58L Aluminum, 74L Aluminum, 116L Aluminum

• ecosmart™: 44ES Aluminum, 66ES Aluminum
S/ 1,269.80 1269.8 PEN
Valve Inlet: C-10 (70-SGI-1 LPM)
70-SGI-1 LPM

• Valve Inlet: C-10 

• Flow Rate: 1 LPM FIXED 

• Gauge PSI: 1800 PSI / 124 bar

• Material: Brass, Nickel Plated

• Fits Cylinder: 34L Aluminum, 58L Aluminum, 74L Aluminum, 105L Aluminum, 116L Aluminum, 103L Steel

• ecosmart™: 44ES Aluminum, 66ES Aluminum
S/ 1,269.80 1269.8 PEN
Profibus DP para BIOLYZER (Afriso)
Profibus DP for BIOLYZER
Brand: AFRISO
Modelo:  69637
S/ 3,591.72 3591.7200000000003 PEN
5200-Female-Front Conector
5200-Female-Front Conector
S/ 181.40 181.4 PEN
Biolyzer-PeltierGasCooler-0909-3400200
Biolyzer-PeltierGasCooler-0909-3400200 
Peltier gas cooler for BIOLYZER
Brand: AFRISO


S/ 3,591.72 3591.7200000000003 PEN
Analizador de Oxigeno, Zirconia, CO2
SERVOPRO 4100 GAS PURITY ANALYSER 
Brand: SERVOMEX
With the following configuration:
Voltage: UK 170-264V 50/60Hz
Background Gas: N2
Module 1: Paramagnetic O2 Purity
Sample System Module 1: Flow Driven
Back Pressure Valve Module 1: Not required
Module 2: 100% CO2
Sample System Module: 2 Flow Driven
Module 3: Zirconia 704 Trace O2
Sample System Module 3: Flow Driven
Oil/Dust Filter, O2 Zr Mod 3: Not required
Chassis Type: Long Chassis
Left Flowmeter: Not Fitted
Right Flowmeter: Not Fitted
Internal Sample Filter: Internal Fitted to Module 1
Autocalibration: Not Fitted
Outputs: 3 extra relays + 2 extra mA
Mounting: 19" Rack Mount Ears Only
S/ 88,849.72 88849.72 PEN
Analizador 4100, 100% CO2- Zirconia, without-flowmeter
Modelo: 4100C1(100% CO2- Zirconia)-without-flowmeter
•CHASSIS TYPE
•Short Chassis (max 2 short or 1 long sensor modules)
•////Module 1: Zirconia 704 Trace O2////
•Sample System Module 2 Flow Driven
•Oil/Dust Filter, O2 Zr Mod 2 Not required
•////GAS SENSOR MODULE 2(1520 IR, 100% CO2) ////
Range: 0 to 100%
Accuracy (intrinsic error) <1% FS
T90 in secs<20@200ml/min
•SAMPLE SYSTEM FOR MODULE 1(Flow Driven PM)
•SAMPLE SYSTEM FOR MODULE 2 (Flow Driven GFX)
•MOUNTING(19" Rack ears only)
•POWER(EUR 170-264V AC)
•User Manual Spanish
S/ 0.00 0.0 PEN
Repuesto TURN TFE RAIN SHIELD (074-0305)
074-0305
4600 1/4 TURN TFE RAIN SHIELD
BRAND: SCOTT
S/ 0.00 0.0 PEN
Regulator with 11 flow(5/8´)
Regulador de flujo con 11 incrementos de flujo,
(0.3, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 5.0, 6.0, 7.0, 8.0, LPM),
Conexión salida púa manguera 5 / 8´-18UNF (C10)
entrada de la válvula, manómetro de 0 a 1200 psig)
Marca: GASCO
S/ 1,269.80 1269.8 PEN
VALVULA DE BOLA 5 VIAS SERIE 43, 1/8 NPT,SS
VALVULA DE BOLA 5 VIAS SERIE
Stainless Steel 1-Piece 40 Series 5-Way Ball Valve, 0.07 Cv, 1/8 in. FNPT
• Body Material  316 Stainless Steel
• Connection 1 Size  1/8 in.
• Connection 1 Type  Female NPT
• Max Temperature with Pressure Rating  150 F 2500 PSIG /65 C 172 BAR
• Actuator Type  Manual
S/ 1,052.12 1052.1200000000001 PEN
Analizador pureza de Oxigeno 100%, CO2100%
SERVOPRO 4100 GAS PURITY ANALYSER PER 1 EA
Brand: SERVOMEX
With the following configuration:
Voltage: UK 170-264V 50/60Hz
Background Gas: N2
Module 1:Paramagnetic O2 Purity
Sample System Module 1:Flow Driven
Back Pressure Valve Module 1: Not required
Module 2:100% CO2
Sample System Module 2: Flow Driven
Chassis Type: Short Chassis
Left Flowmeter: Not Fitted
Right Flowmeter: Not Fitted
Internal Sample Filter: Internal Fitted to Module 1
Autocalibration: Not Fitted
Mounting: 19" Rack Mount Ears Only
User Manual: Spanish
S/ 79,453.20 79453.2 PEN
​CARBON MONOXIDE GAS TRANSMITTER, 0 to 500 PPM, 2% FS, 4 to 122°F (-20 to 50°C)
CARBON MONOXIDE GAS TRANSMITTER 
Brand: DWYER
Series: Field selectable analog outputs 
Gas Sensed: CO, carbon monoxide
Range: CO: 0 to 500 PPM
Accuracy: CO: 2% FS
Temperature Limits: -4 to 122°F (-20 to 50°C)
Storage Temperature: For best sensor life, 32 to 68°F (0 to 20°C).
Humidity Limits: 15 to 90% RH constant; 0 to 99% RH intermittent.
Response Time: <45 s to 90% CO
Power Requirements: GSTC: 10 to 36 VDC or isolated 21.6 to 33 VAC.
Electrical Connection: Removable terminal block, knock outs for conduit fitting.
Enclosure Rating: IP64.
Weight: 1 lb (0.45 kg).
Agency Approvals: CE.
S/ 660.30 660.3000000000001 PEN
SONDA IAQ, CO2, HUMEDAD, TEMP, PRES
SONDA IAQ 

• Marca: TESTO

• para la evaluación de la calidad del aire en interiores,

• medición de CO2

• humedad,temperatura y presión absoluta,

• inclusive soporte de sobremesa

• Rango de medición: 

• 0 ... +50 °C

• 0 ... +100 %HR

• 0 ... +10000

• ppm CO2

• +600 ... +1150 hPa

• Exactitud: ±0.3 °C

• ±2 %HR (+2 ... +98 %HR)

• ±(75 ppm CO2 ±3% del v.m.)

• (0 ... +5000 ppm CO2)±(150 ppm CO2 ±5% del v.m.)

• (+5001 ... +10000 ppm CO2) ±10 hPa
S/ 4,270.16 4270.16 PEN
2700 COMBUSTION CONTROL ANALYZER
1.01.- Suministro de analizador de oxígeno.
=================================
Model:02700D1/10576
•Controller Type Haz. Area FM Div 2
•UK MCERTS Approval
•Sensor Head: Safe Area
•Measurement: Oxygen Sensor Only
•PCB Coating: Not Required
•Aspirator Supply: Air
•Supply Voltage: 100-120Vac 50/60Hz
•Sample Probe: Hastelloy
•Sample Probe Type: Open
•Sample Probe Length: 0.5mr
•Internal Filter / Flametrap: Fitted
•Electrical Conduit Entry: 3/4"NPT
•Sensor Enclosure: Breather Fittings
•Sensor Mounting: Standard
•Sensor Mounting Flange: Standard (4" ANSI)
•Control Unit Mounting  Wall
•Control Unit Enclosure  Blanked
•Utilities Unit: Safe Area Manual Cal, single/dual
•User Manual: English
•Service Manual: English
•Interface Language: English
S/ 64,941.20 64941.200000000004 PEN
H600RSSL1/8-2 (Particulate Filter, 2 µm)
Modelo: H600RSSL1/8-2
•Ham-Let H600RSSL1/8-2 
•(=Swagelok SS-2TF-2), 
•T-Type 
•Particulate Filter, 2 µm
•Max pressure: 6000 psi
•For use with Zirconiza sensor from Servomex
///Servomex Part Numer:  2377-3831/////
S/ 1,269.80 1269.8 PEN
Analizador 4100, O2 Paramagnetico Control, Zirconia
•Voltage EUR 170-264V 50/60Hz
•Background Gas N2
•Module 1 Paramagnetic O2 Control
•Sample System Module 1 Flow Driven
•Back Pressure Valve Module 1 Not required
•Module 2 Zirconia 704 Trace O2
•Sample System Module 2 Flow Driven
•Oil/Dust Filter, O2 Zr Mod 2 Not required
•Chassis Type Short Chassis
•Left Flowmeter Not Fitted
•Right Flowmeter Not Fitted
•Internal Sample Filter Internal Fitted to Module 1
•Autocalibration Not Fitted
•Mounting 19" Rack Mount Ears Only
•User Manual Spanish
S/ 43,536.00 43536.0 PEN
Oxygen Sensor Only (Zr)
Model : S2720D1
Spare 2700D1 Sensor Head
With the following configuration:
Controller Type Safe Area
Sensor Head Type Safe Area
Sensor Head Purge System Not Required (Safe Area)
Measurement Oxygen Sensor Only
Combustible Sensor Not Required
Flow Alarm Not Required
Enhanced Environmental Protect Not Required
Aspirator Supply Air
Supply Voltage 100-120Vac 50/60Hz
Internal Filter / Flametrap Fitted
Electrical Conduit Entry 3/4"NPT
Sensor Enclosure Breather Fittings
Sensor Mounting Standard
User Manual English
El Antiguo Modelo 02720704 ha sido reemplazado por fabrica por el modelo S2720D1.
S/ 39,092.82 39092.82 PEN
TransmisoController Type Haz. Area FM Div 2
Model : S2710D1
Spare 2700D1 Control Unit
With the following configuration:
Controller Type Safe Area
Measurement Oxygen Sensor Only
Enhanced Environmental Protect Not Required
Supply Voltage 100-120Vac 50/60Hz
Electrical Conduit Entry 3/4"NPT
Control Unit Enclosure Blanked
User Manual English
Interface Language English
El Antiguo Modelo 02710734 ha sido reemplazado por fabrica por el modelo S2710D1
S/ 25,727.67 25727.670000000002 PEN
DETECTOR MONOXIDO, CO, 5%
MONOXIDE DETECTOR
Brand: GREYSTONE 
Characteristics:
CO detector, 5%
4-20mA output and adjustable relay
S/ 1,142.82 1142.82 PEN
CASE de reemplazo para PROTEGE
CASE de reemplazo para PROTEGE
Modelo : 096-3249
Marca : Scott
S/ 217.68 217.68 PEN