Conductivity Sensor 1.0 Analog Plus 0-5000uS/cm Aquasensor THERMO
Conductivity/Resistivity Sensor 1.0 Inch
Aquasensor Analog Plus
* Two Eletrode conductivity Sensor
* Sensor Tip: 1.0 Cell (Conductivity)
* Range 0 to 5000 uS/cm
* Electrode Type: Titanium
* Body Material: CPVC
* Temperature Range:  5 C to 75 C / Max. Pressure:  150 Psig at 75C
* Electrode spacing: Concentric
* Cable Lenght: 30 Feet (9 Mts)
S/ 0.00 0.0 PEN
Diferential ORP Sensor 1.0 inch Range: -2100mV to +2100mV / Resolution:0.1mV Cable Lenght: 30 Feet
Diferential ORP Sensor 1.0 inch
AquaSensors Analog Plus
•    Range: -2100mV to +2100mV / Resolution:0.1mV
•    Temperature Range: -5 C a 75 C (CPVC)
•    Maximun Pressure: 100 Psig -  95C
•    Maximun Flow rate: 10 ft/sec
* 1 inch NPT Mounting
* Body Materia: CPCV
* Eletrode Type: Platinium
* Sensor Tip: Protected
* Temperature Element: PT1000
* Ground Rod: Titanium
* Cable Lenght: 30 Feet
More Details: See Datasheet Atached
S/ 3,718.70 3718.7000000000003 PEN
ORION PH Sensor 1.0 inch 0-14 pH Cable Lenght 30' (9.14 mts)
ORION PH Sensor 1.0 inch
Range: 0-14 pH
ROSS Electrode
Resolution: 0.01 PH
Accuracy: 0.1 pH
Precision: 0.05 pH - 0.5C
Temperature: -5 to 95C
Pressure: 0 - 100 Psi
Maximun Flow Rate: 10 ft/sec
Proces Conection: 1" NPT
Sensor Material: PEEk
O-ring : VITON
Cable Lenght 30' (9.14 mts)
Sensor temperature: PT-1000 (-5 to 200C)
Brand: Thermo Scientific
More details: See PDF Attached
S/ 3,000.36 3000.36 PEN
Diisopropylamine Application Consumables Package Without DIPA solutio
Diisopropylamine Application Consumables Package Without DIPA solution
ORION 2111XP Sodium Analyzer
•For one year operation, includes
•6 diffusion tubing assemblies
•Reagent bottle adapter
•Sodium standard solutions kit (2xbottle of standard 1, 2 bottle of standard 2, 1 bottle etch solution)
•01 Sodium electrode
•01 Reference electrode,
•5 x 2 oz. bottles of reference electrode filling solution
•O-ring kit
•Check valve
•Pipet tips (0.1 mL)
•Restriction tubing assembly and
•Inlet filters
S/ 10,067.70 10067.7 PEN
KIT DIPA
2111XD
DIPA Application Package
DIPA reagent bottle adapter and
Diffusion tubing
S/ 0.00 0.0 PEN
Silica Analyzer + bottles + pump tubing kit
ORION 223000
2230 Silica Analyzer - Contains Sillica Analyzer,
Blank reagent bottles (3), Blank standard bottle (1),
and pump tubing kit (installed).
More details, see PDF attached
S/ 44,080.20 44080.200000000004 PEN
Cell Conductivity
SEN RS 3/4 INNPT 0.1C TI 2IN 30FT T
Cell, Conductivity, k=0.1 with 30 ft. Cable, Thornton #240-220
Marca: METTLER TOLEDO
S/ 0.00 0.0 PEN
Low-Level Chloride Analyzer
Thermo Scientific Orion 2117LL Low-Level Chloride Analyzer
* Anexo Hoja de Especificaciones
S/ 0.00 0.0 PEN
Sodium Monitor-Expandable Platform, Range: 0.10 ppb to 10 ppm, =/- 5% or 0.1 ppb, Output: 2 x 4-20 m
Thermo Scientific Orion 2111XP Sodium Analyzer
Sodium Monitor-Expandable Platform, for Pure Water, double known addition calibration technique with off-line calibration.
Reagent: Diisopropylamine (DIPA)
Range: 0.10 ppb to 10 ppm
Resolution: 1,2 o 3 digits
Accuracy (with DKA cal): =/- 5% or 0.1 ppb
Sample conditions: Temp: 5 to 45° C / Inlet Pressure: 8 to 100 psi / Flow rate: 40mL/min
Calibration: DKA calibration
Output: 2 x 4-20 mA (Sodium & temperature)
Relays: 3 Relays (250Vac, 5 A, 30 VDC)
Power: 85-132 or 170-264 Vac
INCLUDE:
• Sodium electrode, Reference electrode, ATC Probe, Sodium Standard solution Kit, application package (DIPA reagent bottle adaptor, diffusion tubing), CD User Guide
More specifications please see Datasheet attached.
S/ 0.00 0.0 PEN
PH222 (Ph Meter)
PH222 (Ph Meter)
Marca Lutron (TAIWAN)
S/ 380.94 380.94 PEN
FINNTIP 50-1000uL
MODEL: 94060710
FINNTIP 50-1000uL
BRAND: ORION 
Paq x 960 Unid
2111XP Sodium Analyzer






S/ 0.00 0.0 PEN
KIT DIPA Consumable Package
Diisopropylamine Application Consumables Package (DIPA)
ORION 2111XP Sodium Analyzer
For ONE YEAR operation, includes
• 6 x 0.8 L bottles of DIPA reagent (211191)
• 6 diffusion tubing assemblies (211194)
• Reagent bottle adapter (2111RBA)
• Sodium standard solutions kit (181140)
• Sodium electrode (210045)
• Reference electrode (210056),
• 5 x 2 oz. bottles of reference electrode filling solution (181073)
• O-ring kit
• Check valve
• Pipet tips (0.1 mL),
• Restriction tubing assembly and
• Inlet filters
S/ 13,931.52 13931.52 PEN
ORION Reagent Silica Process KIT
Kit de Reagentes (Reagent 1, Reagent 2, Reagent 3)
For Silice Analyzer Model: ORION 2230XP
S/ 0.00 0.0 PEN
Kit de tubos principales 2230XP
Kit de tubos principales 2230XP
​2230XPTK
Kit completo de Tubos Principales para Reagentes, Standard y muestras
S/ 3,573.58 3573.58 PEN
ORION Maintenance Kit
2230MK
• Kit de mantenimiento con Tubing de Arnés (Para bombas peristálticas) y su respectivo lubricante
• Analizador de Silice
THERMO SCIENTIFIC (ORION)
S/ 1,324.22 1324.22 PEN
ORION 200 ppb Calibration Standard
200 ppb Calibration Standard
ORION 2230 Silica Analyzer
S/ 696.58 696.58 PEN
ORION Main Tubing Kit , Analizador de Silice
Kit completo de Tuberías Principales para Reagentes, Standard y Muestra
Analizador de Silice
P/N: 2230TK
THERMO SCIENTIFIC (ORION)
 
S/ 4,709.14 4709.14 PEN
Silica Analyze, Rango de medida: 0-5000 ppb, Absorción óptica a 810 nm, 2 x 4-20mA output, 100-240V
2230XP Silica Analyzer
Detección temprana en Línea para niveles bajos de silice
•    Rango de medida: 0-5000 ppb
•    Tiempo de respuesta: menos de 15 minutos por análisis
•    Límite de detección: 0.5 ppb
•    Método: Absorción óptica a 810 nm
•    Flujo de muestra requerida: 50-1000 ml/min
•    Alimentación: 100-240VAC, 100w 50/60Hz
•    Salida Analógica: Dos salidas de 4-20mA
•    Relés: 4 SPDT relays 5A a 220v programable (Se programan para alarmas, indicación de fin de ciclo de medida, etc)
•    Comunicación Digital: RS232 ASCII para reporte de data
•    Display Grafico Digital LCD con Luz de fondo (Backlight)
•    Integridad de Protección:
 NEMA 12 (gabinete electrónico),
NEMA 4X (Gabinete de Fluidos)
•    GRAB SAMPLER Capability: Permite programar el equipo para que el análisis de muestras externas no genere señal de 4-20mA y solo se muestre en el Display.
Para Mayor información, revisar hoja de Datos adjunta
S/ 58,955.00 58955.0 PEN
THERMO AQUASENSOR Turbidity Sensor+Transmitter+Head Wash
TURBIDITY SENSOR
==================
CODE: RT1-243
AQUASENSOR DataStick
* Wide-Range Turbidity
* 0-4000 NTU Measurement Range
* Resolution: 0.1 NTU
* Measuring Principle: Nephelometric
* Temp Range: -5 to 50 C
* Maximum Pressure: 65 Psi (450 kPa)
* Maximum Flow Rate: 10ft/sec (1020 m3/h)
* 90 Degree and 180 degree light paths
* Plug and play industrial communication adaptor
* Back Body and communication Material: 316 Stainless Steel
* Process Connection 1” NPT
* Cable Length: 20 mts

TRANSMITTER
===========
CODE: AV38-CB0C2
AV38 (Local Monitor Controller)
• 02 Analog Output 4-20mA
• 02 Form “C” Relay (1 amp with NO and NC) for Control, Alarm, Wash
• Mounting: 1/4 DIN NEMA 4X Wall Mount Enclosure
• Power: 100 to 240 VAC
• Approvals: Meet s CE requirements
Please read Datasheet for more information attached to this Quote

WASH HEAD ASSEMBLY
===================
CODE: MH1222
S/ 0.00 0.0 PEN
ORION CHLORINE XP Rango de Medición: 0 a 10000 ppb, Precisión: +/- 5% , Tiempo de Ciclo: 2 to 10 M
ORION CHLORINE XP (CXP71)
• Medición de CLORO LIBRE sin interferencia por fluctuaciones de PH
• Medición en Línea aprobado por USEPA; Certificaciones CSA, CE
* Rango de Medición: 0 a 10000 ppb (0 a 10 ppm)
* Mínimo Limite de Detección: 10 ppb (0.01 ppm)
* Precisión: +/- 5%
* Tiempo de Ciclo: 2 to 10 Minutos
* Reemplazo Regentes: 1-2 Meses
* Reagentes Usados: DPD (hasta 2 meses a 5min por ciclo)
• Salidas Analógicas: 02 salidas de 4-20mA (Estándar); (Opcional: 04 salidas de 4-20mA)
• Alarma: Opcional ; Medición de PH: Opcional
• Alimentación: 220-230 VAC, 50/60 Hz, 0.5A (Opcional: 100-115 VAC)
More Details please see Datsheet attached
S/ 0.00 0.0 PEN