Mass Flowmeter Coriolis TME,Range min/max: 0-600 /0-12000 kg/h Pressure rating: 40 bar
Coriolis-Mass Flow Meter<br />
Model code Sensor: TME-S-90-309B-0-L-1-0-2-0<br />
Model code Transmitter: UMC4-B-1-1-A-0-0<br />
*********************************************<br />
Fluid: ALIMET (SAN FERNANDO - AREQUIPA)<br />
*********************************************<br />
***Process conditions:<br />
Flow rate [kg/min]: 2 - 16, 5<br />
Density [kg/m3]: 1214<br />
Viscosity [cP]: 127<br />
Fluid temperature [°C]: 20<br />
Line Pressure [bar g]: 5, 31<br />
***Sensor Information:<br />
TME-S-90<br />
Range min/max: 0-600 /0-12000 kg/h<br />
Pressure rating: 40 bar<br />
Ingress protection Sensor: IP65 (EN60529)<br />
309B<br />
Process connection: DN25 PN40 Form B1 DIN/EN1092<br />
Installation Length: 400 mm<br />
0: Heating/cooling: without<br />
L: Flow direction: Left to Right<br />
1: Sensor configuration: Integral mount, Temperature service rating: -20 to 100°C<br />
0: Approvals: without approval<br />
2: Test report, 2.2<br />
***Transmitter:<br />
Type: UMC4<br />
B: Mounting: Integral mount, Conduit port opening: M20x1, 5<br />
1: Display/Interface board: Integral within transmitter housing<br />
1: Power supply: 90-265V AC, 50/60Hz<br />
A:<br />
Analog output 1: 4-20 mA With HART®-protocol: Mass flow<br />
Analog output 2: 4-20 mA: Mass flow, temperature, Volume flow<br />
Pulse output 1: ...Imp/kg passive<br />
Status output 2: passive: Forward and backward flow, Alarm, MIN/MAX flow, MIN/MAX, density, MIN/MAX temperature.<br />
0: Approval: none<br />
0: Type of protection (signal output), none<br />
***Performance Characteristics:<br />
Accuracy: ± 0, 15% of actual flow<br />
+ zero-point-stability<br />
Repeatability: ± 0,075% of actual flow<br />
Pressure loss: 0,35bar at flow 16, 5 kg/min<br />
Datasheet:<br />
http://www.heinrichs.eu/uploads/tx_rsbproductdownload/tme_umc4_db_en.pdf
Brand: KOBOLD |