Ultrasonic Flow Meter/-Monitor/-Counter/-Doser,Max. temperature/pressure 120 °C / 16 bar
Model: DUK-22-N9H-G14R-L<br />
Brand: Kobold<br />
[DUK-22]:<br />
Operating principle Ultrasonic<br />
Mounting position all directions<br />
Indication/Output see electronic version<br />
Max. temperature/pressure 120 °C / 16 bar <br />
Protection IP 65<br />
Seal FPM<br />
Sensor Housing St. st. <br />
[N9H]:Measuring range/connection, 1…250 L/min, 2 NPT female  <br />
[G14R]: Evaluation electronic for DUK <br />
Dosing electronic, 4-20 mA, 24 VDC, 1 m cable connection <br />
[L]: Flow direction from left to right <br />
*************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/duk-gb-flow.pdf
S/ 5,791.69 5791.6900000000005 PEN
Medidor, monitor, contador y dosificador de flujo ultrasónico (1…250 L/min)
<strong>Ultrasonic Flow Meter/-Monitor/-Counter/-Doser<br />
Model: DUK-21-N9H-G14R-L<br />
Brand: Kobold (Alemania)</strong><br />
[DUK-21]:<br />
Operating principle Ultrasonic<br />
Mounting position all directions<br />
Indication/Output see electronic version<br />
Max. temperature/pressure 120 °C / 16 bar <br />
Protection IP 65<br />
Seal FPM<br />
Sensor Housing Brass <br />
[N9H]:Measuring range/connection, 1…250 L/min, 2 NPT female  <br />
[G14R]: Evaluation electronic for DUK <br />
Dosing electronic, 4-20 mA, 24 VDC, 1 m cable connection <br />
[L]: Flow direction from left to right
S/ 4,197.95 4197.95 PEN
Flow Indicator and Switch with Paddle and Bellows. Output 1: microswitch/SPDT. Connection: DN 80. In
Flow Indicator and Switch with Paddle and Bellows<br />
Model: DWU-3-5-W80-3-R-T-0<br />
Brand: Kobold<br />
[DWU-3]:<br />
Operating principle paddle-bellow<br />
Indication pointer indication<br />
Flow direction in direction of the arrow<br />
Output 1 microswitch/SPDT<br />
max. temperature 100 °C<br />
Connection weld-on flan.<br />
[5]: Material combination: steel<br />
[W80]: Connection: for tube nom. diameter DN 80<br />
[3]: Signal lamp: 24 VDC<br />
[R]: Flow direction: flow from right to left<br />
[T]: Location of indicator: above lead<br />
[0]: w/o option<br />
***************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/dwu-gb-flow.pdf
S/ 5,167.57 5167.57 PEN
Flow Indicator and Switch with Paddle and Bellows,max. temperature 100 °C ,Connection: for tube nom.
Model: DWU-3-5-W1F-3-R-T-0<br />
Brand: Kobold <br />
[DWU-3]: <br />
Operating principle paddle-bellow<br />
Indication pointer indication<br />
Flow direction in direction of the arrow<br />
Output 1 microswitch/SPDT<br />
max. temperature 100 °C <br />
Connection weld-on flan.<br />
[5]: Material combination: steel<br />
[W1F]: Connection: for tube nom. diam. DN 150 <br />
[3]: Signal lamp: 24 VDC<br />
[R]: Flow direction: flow from right to left <br />
[T]: Location of indicator: above lead <br />
[0]: w/o option<br />
***************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/dwu-gb-flow.pdf
S/ 5,167.57 5167.57 PEN
Viscosity Compensated Flowmeter /-switch,Max. temperature 100 °C,,Max. pressure 250 bar
Model: VKM-11-02-R0-N08-B-L<br />
Brand: Kobold<br />
[VKM-11]:<br />
Operating principle variable area<br />
Mounting position all directions<br />
Flow direction in direction of the arrow<br />
Body material Brass <br />
Seal NBR <br />
Switch point adjustable<br />
Accuracy ±4 % FS  (at 105 mm²/s)<br />
Max. temperature 100 °C<br />
Max. pressure 250 bar <br />
Viscosity range 1...540 mm²/s<br />
[02]: Measuring range: 0,1...0,45 L/min oil <br />
[R0]: Contact 1 N/O <br />
[N08]*: Connection 1/4 NPT female <br />
* for <= 9 L/min<br />
[B]: Option special connection, on top female thread, bottom BVB <br />
[L]: Flow direction, from left <br />
********************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/vkm-gb-flow.pdf
S/ 1,994.96 1994.96 PEN
Medidor de flujo de viscosidad compensada
<strong>Viscosity Compensated Flowmeter /-switch<br />
Model: VKM-31-09-U0-R25-0-B<br />
Brand: Kobold (Alemania)</strong><br />
[VKM-31]:<br />
Operating principle variable area<br />
Mounting position all directions<br />
Flow direction in direction of the arrow<br />
Body material Brass<br />
Seal NBR<br />
Switch point adjustable<br />
Accuracy ±4 % FS (at 105 mm²/s)<br />
Max. temperature 100 °C<br />
Max. pressure 250 bar<br />
Viscosity range 1...540 mm²/s<br />
[09]: Measuring range, 4...40 L/min oil<br />
[U0]: Contact 1 SPDT<br />
[R25]: ****Connection G 1 female<br />
****for >= 40 L/min<br />
[0]: Option special connection, w/o<br />
[B]: Flow direction, from bottom
S/ 3,243.20 3243.2000000000003 PEN
All-Metal-Flowmeter
Model: BGN-S15-6830I0G0-0-S50-0-K<br />
Brand: Kobold - Heinrichs<br />
Type: BGN-120-25/10/CLAMP/DIN-160<br />
Function<br />
Measuring principale: Float-element<br />
Operating conditions<br />
Fitting position: vertical<br />
Flow direction: bottom to top<br />
Performance characteristics<br />
Measured error (local): ±1,6% of actual flow, acc. VDI/VDE 3513-2 (qG=50%)<br />
Process conditions<br />
Range [N1/h]: 13 - 100<br />
Fluid: Air<br />
Density [kg/Nm3]: 1,293<br />
Viscosity [mm2/s]: 0,017<br />
Process temperature [°C]: 27 (max. 80)<br />
Process pressure [pe bar]: 1<br />
Mechanical construction<br />
Material - body: SS 1.4571 / 1.4404<br />
Material - clamp socket: SS 1.4404<br />
Material - float: SS 1.4571 / 1.4404<br />
Material - measuring ring: SS 1.4571 / 1.4404<br />
Type - float: KU160 (I)<br />
(not removable)<br />
Measuring ring: 14 mm i. d.<br />
Nominal - pressure: 10 bar<br />
Design: Kobold<br />
Process Connection - acc. DIN32676<br />
Inflow (DN1): DN25 - CLAMP socket<br />
Outflow (DN2): DN25 - CLAMP socket<br />
Overall length [mm]: 300<br />
Accessory<br />
-gas damping<br />
************************************************************************<br />
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/bgn_db_en.pdf
S/ 6,435.38 6435.38 PEN
ERS-SPARES for DON
ERS-SPARES for DON<br />
Model: DON-110HN24Z3N0  <br />
Brand: Kobold<br />
Spares for DON<br />
Type: DON-110HN24Z3N0  <br />
Ser.-No.: 392663D<br />
Info customer : only oval wheels
S/ 167.18 167.18 PEN
Flow Limiter
Model: REG-1-2-20-D<br />
Brand: Kobold<br />
[REG-1]:<br />
operating temperature max. 300 °C<br />
operating pressure max. 200 bar<br />
differential pressure min. 2 bar / max. 10 bar<br />
type of thread, inside<br />
size of thread, G 1/2<br />
[2]: housing material, st. st. 1.4301<br />
[20]: flow rate, 20 L/min<br />
[D]: Version, Longer version (DIN thread)<br />
******************************************<br />
Datasheet: http://www.kobold.com/uploads/files/z1gb_reg.pdf
S/ 408.65 408.65000000000003 PEN
Flow Limiter, flow rate, 8 L/min
Flow Limiter<br />
Model: REG-1-2-08-D<br />
Brand: Kobold<br />
[REG-1]:<br />
operating temperature max. 300 °C<br />
operating pressure max. 200 bar<br />
differential pressure min. 2 bar / max. 10 bar<br />
type of thread, inside<br />
size of thread, G 1/2<br />
[2]: housing material, st. st. 1.4301<br />
[08]: flow rate, 8 L/min<br />
[D]: Version, Longer version (DIN thread)<br />
 
S/ 434.66 434.66 PEN
magnetic inductive flowmeter, 288 m³/h, DN20
Model: EP-H-210R-1-S-S-1-0 / UMF2-A-1-1-F-0BK<br />
Brand: Kobold-Heinrichs<br />
[EP-H]:<br />
Material - lining: hard-rubber, standard 3 stainless steel electrodes<br />
Temperature, 0°C...80°C<br />
[210R]: Process Connection, 4" Class 150 RF ASME B16.5-2003<br />
Max. measuring range (Water 20°C, 1 mPas), 288 m³/h<br />
Installation length, 250mm<br />
[1]: Material flanges, steel (painted)<br />
[S]: Material electrodes, Stainless steel,<br />
standard for hard rubber, soft rubber<br />
[S]: Earthing electrode (from DN20...),  Stainless steel,<br />
[1]: Transmitter mounting, integrated transmitter<br />
Protection class sensor, IP67<br />
[0]: Approvals, without<br /><br />
[UMF2-A]:<br />
Mounting, IP67 integrated transmitter IP67 standard, ½" NPT (f)<br />
[1]: Display and control unit, integrated<br />
[1]: Power supply, 230V AC (+10%, -15%), 50/60Hz<br />
[F]: Output:<br />
current output 1: 0(4) - 20mA      <br />
pulse output:  passive Um=24VDC     <br />
status output: passive Um=24VDC<br />
[0BK]: Design, Kobold
S/ 7,805.22 7805.22 PEN
Oval Gear Flow Meter/Counter, Measuring range, 50-580 L/min
Model: DON-8-40H-A9-1-H0-M-0<br />
Brand: Kobold<br />
[DON-8]:<br />
Operating principle: Gear Wheel<br />
Mounting position: horizontal / vertical<br />
Flow direction: in direction of the arrow<br />
Max. temperature: 80°C<br />
Max. pressure: 16-100 Bar<br />
Accuracy: ±0,2 % …1 % of reading<br />
Housing material: st. steel<br />
Rotor material: PPS<br />
[40H]: Measuring range, 50-580 L/min<br />
[A9]: Mech. connection, for meas. range 40H, ANSI flange 2" 150 lbs<br />
[1]: Seal, FKM for DON-x30…DON-x40<br />
[H0]: Electronic, Pulse output Hallsensor/Reed switch, Push Pull (8-30 VDC)<br />
[M]: Cable entry, M20<br />
[0]: Options, without
S/ 11,921.44 11921.44 PEN
ERS-SPARES for V31
ERS-SPARES for V31<br />
Model: V31-203R3F 06D9W FFS0040000000K<br />
Brand: Heinrichs - Kobold<br />
Spares for V31<br />
Type: V31-203R3F 06D9W FFS0040000000K<br />
Ser.-No.: 328054<br />
Info customer : Fluid was spilled und damaged the parts<br />
new parts:<br />
- 1 x Material-body (SS 1.4301)<br />
- 2 x Sleeve nut (orange)
S/ 832.16 832.16 PEN
Replacement Kit (Glass and Seal) for DAT
<strong>Replacement Kit (Glass and Seal) for DAT<br />
For model: DAR-2302H-A20Q    </strong><br />
Gasket Seals and Glass Sets, DIN 7080 borosilicate glass material,<br />
and graphite seal gasket, suitable for pressure and temp max. of 40 bar / 150 ° C
S/ 668.70 668.7 PEN
All-Metal Variable Area Flowmeter BGN, Range (water 20°C, 1 mPas): H2O: 16 - 160 l/h
All-Metal Variable Area Flowmeter BGN<br />
Model: BGN-S-15-203R-I-0-0-0-0-S-5-6-0-H<br />
Brand: Kobold – Heinrichs<br />
[BGN]: Model<br />
[S15]: Model, Stainless Steel, process temperature  = 350°C<br />
[203R]: Connection, size, 1" Class 150 RF ASME B16.5-2003<br />
[I]: Range (water 20°C, 1 mPas): H2O: 16 - 160 l/h<br />
[0]: Heating / cooling, without heating / Cooling<br />
[0]: Damping / spring stop, without<br />
[0]: Self draining, without<br />
[0]: Certificates, without  <br />
[S]: Display,<br />
Standard display housing,<br />
Process temperature = 150°C for electrical output,<br />
Process temperature = 200°C for local indication<br />
[5]: Scale, Measuring range-Scale (Media)<br />
[6]: Switches, Transmitter ES with HART-protocol, 4-20 mA, EEx ia       <br />
Ambient temperature, -40° to +70°C<br />
[0]: Accessories, without<br />
[H]: Design, Heinrichs<br />
********************************************************************<br />
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/bgn_db_en.pdf
S/ 5,349.60 5349.6 PEN
Calorimetric Flowswitch, Compact Version. Sensor Length = 50 mm. Connection, 3/4" NPT. Output: PNP/
Calorimetric Flowswitch, Compact Version<br />
Model: KAL-K8-4-20-S-PG3<br />
Brand: Kobold<br />
[KAL-K8]:<br />
Operating principle calorimetric<br />
Mounting position all directions<br />
Indication DUO-LED and LED-chain<br />
max. temperature 80 °C (120 °C for KAL-KH)<br />
max. pressure 100 bar<br />
Protection class IP 65<br />
Connection thread NPT<br />
Sensor length (C) = 50 mm<br />
[4]: Probe material, st.st. 1.4571  <br />
[20]: Connection, 3/4"NPT<br />
[S]: Contact version, N/O<br />
[PG3]: Electron. connection/power supply, M 16x1,5 PNP/NPN, 24 VDC  <br />
***************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/kal-k-gb-flow.pdf
S/ 2,139.84 2139.84 PEN
Low Volume Flowmeters
Low Volume Flowmeters<br />
Model: KSV-24-35L<br />
Brand: Kobold <br />
[KSV-24]: <br />
Operating principle variable area<br />
Mounting position vertical, from bottom<br />
Accuracy ± 6% FS<br />
Max. temperature 120 °C<br />
Max. pressure 6 bar<br />
Needle valve (only KSV-1) bottom<br />
Connection 1/8 NPT female on rear<br />
st. st.<br />
Seal, FPM<br />
Housing material Polysulfone<br />
[35L]: KSV-2...<br />
Measuring range (w/o needle valve), 0,25...1,5 Nm³/h air <br />
**********************************************************<br />
Datasheet: http://www.kobold.com/uploads/files/s1gb_ksv-1.pdf
S/ 531.25 531.25 PEN
Plastic Flowmeter/-switch Measuring range, 1200...12000 L/h water or 45...370 Nm³/h air
Plastic Flowmeter/-switch<br />
Model: KSM-1-120-H-P40-R0<br />
Brand: Kobold <br />
[KSM-1]:<br />
Operating principle: variable area<br />
Mounting position: vertical<br />
Flow direction: from bottom<br />
Armature material: Trogamide <br />
Accuracy: ±4 % FS<br />
Max. temperature 60 °C <br />
Max. pressure 16 bar<br />
[120]: Measuring range, 1200...12000 L/h water   or   45...370 Nm³/h air* <br />
[H]: either   scales for liquid media, L/h water <br />
[P40]: Option connection for size 060 + 120, PVC G 1 1/2 female <br />
[R0]: Option contact, w/o contact
S/ 2,934.85 2934.85 PEN
Flujómetro Magnético Inductivo Compacto (0,05...1,0 L/min)
<strong>Compact Magnetic Inductive Flow Meter<br />
Brand: MIK-5NA-10-E-C34P<br />
Model: Kobold</strong><br />
[MIK-5NA]:<br />
Operating principle Magnetic Inductive<br />
Mounting position all directions<br />
Max. temperature/pressure 80 °C / 10 bar<br />
Protection IP 65<br />
Housing PPS <br />
Electrodes St. st.<br />
Seal NBR<br />
[10]: Measuring range (liquid >30 µS/cm), 0,05...1,0 L/min G 1/2 male <br />
[E]: Connection set, G ¾ - Ø10/13,5 mm <br />
[C34P]*: Evaluation electronic for MIK, 24 VDC, 4-20 mA, 1x PNP <br />
*Please specify flow direction in writing
S/ 2,678.52 2678.52 PEN
Coriolis Massflowmeter,Process t°emperature, -4° to 212F, -20° to 100°C,Range, min. 0-60 kg/h - max.
Coriolis Massflowmeter<br />
Model: TMU-S-008-6010-A-0-0-A-0-1-0-0-H/UMC4-B-1-1-A-0-0<br />
Brand: Heinrichs - Kobold<br />
[TMU-S]: <br />
Wetted materials, Stainless steel <br />
[008]: Meter line size, DN8, ANSI ¼" <br />
Range, min. 0-60 kg/h - max. 0-600 kg/h<br />
[6010]: Process connection, ¼" NPT (f) <br />
Installation length, 300 mm<br />
[A]: Containment options, Stainless steel containment 1.4301 (304) <br />
[0]: Heating / cooling, None<br />
[0]: Connection for heating / cooling, None<br />
[A]: Sensor configuration, Integral mount transmitter <br />
Process temperature, -4° to 212°F, -20° to 100°C <br />
Sensor Cable Connection, IP66<br />
[0]: Approvals, None<br />
[1]: Calibration flow, Standard, 3-point<br />
[0]: Calibration density, None<br />
[0]: Supplementary equipment, None<br />
[H]: Design, Kobold<br />
**********************************************************************<br />
[UMC4-B]:<br />
Mounting, Integral mount <br />
Conduit port opening, M20 x 1,5 <br />
[1]: Display / Interface board, Integral within transmitter housing,<br />
for ambient temperature up to 60°C <br />
[1]: Power supply, 90 - 265V AC, 50/60Hz <br />
[A]: Outputs<br />
Analog output 1: 4 - 20mA with HART®<br />
Analog output 2: 4 - 20mA<br />
Pulse output: passive Um=30V DC<br />
Status output: passive Um=30V DC<br />
[0]: Approvals, None<br />
[0]: Type of protection (signal output), none<br />
*****************************************************************<br />
Datasheet: http://www.heinrichs.eu/uploads/tx_rsbproductdownload/tmu_da_en.pdf
S/ 22,319.72 22319.72 PEN