FLUJOMETRO TIPO TURBINA, 5.3 – 53 GPM, 500 PSI, Salida de Pulso, 4 A 20 mA.

https://industrial.intrial.com.pe/web/image/product.template/6095/image_1920?unique=1fb539d

FLUJOMETRO TIPO TURBINA

• Marca: AW LAKE
MODELO: TRG-1110+MAG-PB+RT-Ex15A
• TAG-No. 135-FQI-052
TRG-1110

• Rango de Flujo: 5.3 – 53 GPM

• K-Factor *(Pulsos/ gal): 800 

• Conexión: 1 1/2” NPT macho 

• Filtración (micras): 300

• Rango de Presión (psi): 5000

• Material del cuerpo: 316SS 

• Accuracy: +- 0.5%



MAG-PB

• Salida de Pulsos (MAG Hall Effect Pickup)

• Marca: AW LAKE



RT-Ex15A 

MONITOR DE FLUJO CON PROTOCOLO DE COMUNICACIÓN HART

• Marca:AW FLOW METERS(USA)

• Flow rate / total screens

• 4-20mA rate output and scaled pulse output

• Gate time function

• HART communication protocol

• Test Point for external frequency input

• Programmable outputs

• Magnetically select any key functions

• Power Requirement:15-24 VDC/150mA(customer supplied)

• Analog Output 4-20 mA:16-bit D/A Converter ,3 wire or 2 wire plus seperate supply

• Max. Load Impedance: 500 ohm.

• Enclosure Certifications:

• Class I,Groups A,B,C,D NEMA 4X

• Class II,Groups E,F,G FM Class No. 3615

• Class III FM y CSA approval pending

• Atex:EEx d IIC,IP68 Copper Free Standards

• Sensor/Monitor Frequency Range:0-4000 Hz

• Temperature Ratings:-20 to 60°C(-4 to 140°F Ambient

• Connection:3/4''NPT Conduit Provisions

• Two Opto-Isolated Open-Collector Outputs:

• 5-30 VDC Rating,50 mA Max.(Minimum Load

• Impedance Required,600 Ohm 30 VDC) 

• Opto-Isolated Reset Input:5-30 VDC Input,3.3Kohm Impedance

• Meter Compatability:TR and TRG Turbine FlowMeters

S/ 10,067.65 10067.65 PEN S/ 10,067.65

Not Available For Sale

  • Marca
  • Línea

Esta combinación no existe.

Marca: AW LAKE
Línea: AW-LAKE (CM)

Términos y condiciones
Garantía de devolución de 30 días
Envío: 2-3 días laborales