Grab Sample Conditioning Panel SL200H Special
SL200H-SPECIAL
Sample: Boiler Water 120C° at 60 BARG
Conditioning Panel for On-Line Analysis
Consisting of the following components:
* 1/4 in. Sample Inlet Isolation Valve
* 1/4 in. High Pressure (Sample Inlet) Blowdown Valve
* Primary Sample Cooler, Sentry Model TLR4225
* 3-Way Cooling Water Inlet Valve, with drain
* Globe Valve on the Cooling Water Outlet
* Cooling Water Sight Gauge
* Cooling Water Valve Materials are Stainless Steel
* Sentry VREL High Pressure Reducing Valve
* Sentry TSV with a Setpoint of 120°F(49°C)
* Total Flow Indicator, 0-1600 cc/min
* Temperature Gauge, 0-250°F/-20-120°C
* Sentry BPRV with a Setpoint of 20 psig/1.4 barg
* 304 SS Sample Sink
All components are factory mounted on a 12 in. W x 36 in. H, T304SS backplate.
All sample tubing throughout panel is SA249, T316 SS.
QA Documents Provided:
* QAF 1050 Manufacture Certificate for Testing and Material – Single Line
* QAF 1030 Product Inspection Checklist - Includes Hydrotest Results
Marca: SENTRY |
Línea: SENTRY (CM) |