INSERTION ELECTROMAGNETIC FLOW TRANSMITTER
INSERTION ELECTROMAGNETIC FLOW TRANSMITTER
Brand: DWYER
Service: Compatible clean or dirty non coating, conductive liquids
Series IEF
Range: 0 to 20 ft/s (0 to 6 m/s).*
T: Accuracy: High accuracy 10˝ (250 mm) pipe; 1% of reading
N: Process Connection:1˝ male NPT
CND: Housing Electrical Connection:1/2˝ female NPT
conduit connection without cable
LCD: Options: Integral LCD display
Temperature Limits:
Ambient: -20 to 160°F (-29 to 71°C)
Process: 15 to 250°F (-9 to 121°C)
Storage: -40 to 185°F (-40 to 85°C)
Pressure Limits: 400 psi (27.6 bar) @
100º F (37.8°C).
Pressure Drop: < 0.1 psi at 12 ft/s in 4˝
(101.6 mm) and larger pipe.
Outputs:
(1) Analog: 4-20 mA, 0-5 V, 0-10 V or
2-10 V (display selectable);
(1) Pulse/Frequency: 0-15 V peak pulse,
0 to 500 Hz or scalable pulse output
(display selectable);
(2) Alarm: (1) Empty pipe detection or
minimum/maximum velocity, (display
selectable); (1) Reverse flow output
indication.
Power Requirements: 12-42.4 VDC
.25 A @ 24 VDC; 12-36 VAC.