INDICADOR VISUAL DE FLUJO, 200°F (93°C)., 1/4" male NPT.
SIGHT WINDOW
Model : SFI-550-14
Brand: DWYER
Service: Compatible gases and liquids
Wetted Materials: Window: glass; Body: plated steel.
Temperature Limit: 200°F (93°C).
Pressure Limit:125 psig (8.6 bar).
Connections:1/4" male NPT.


S/ 127.58 127.58 PEN
4-section high pressure flow divider, flow: 160 l / min
NEW HIGH PRESSURE FLOW DIVIDER
Brand:  Power Hydraulik
4-section high pressure flow divider
max. inlet flow: 160 l / min
max. working pressure continuous: 240 bar
Option "L"= with "with inductive sensor BES 516-300-S135-D-PU05"
including mounting feet
net weight: 20,0 kg / a piece
S/ 10,898.55 10898.550000000001 PEN
​MINI-SIZE FLOW SWITCHES, 1/2" NPT, SPDT, Stainless Steel
MINI-SIZE FLOW SWITCHES
Brand: DWYER
Upper Housing Material: Stainless Steel
Lower Housing Material: Stainless Steel
Switch Type: SPDT
Line Connection Size: 1/2" NPT
Tee/Bushing Material: Stainless Steel
S/ 0.00 0.0 PEN
MINI OIL METER, 20mm in nominal dia, L/h, ANSI 150RF (FCD450)
MINI OIL METER
Brand: OVAL
Size: 20mm in nominal dia
Flange Rating and Body Materal: ANSI 150RF (FCD450)
Meter Assembly: Direct-reading totalizer
Direct-reading totalizer: L
Remote flow indicator: L/h
S/ 0.00 0.0 PEN
​TRANSMISOR DE FLUJO, -40 a 177°C, 150psi, ¾”NPT-M, 1 a 6” (152,4mm)
TRANSMISOR DE FLUJO
Marca: FCI
Aplicación: Aire
Montaje en tubería horizontal
Dirección del fluido: Izquierda a derecha o Vertical hacia abajo
Carcasa: Aluminio
Rango de temperatura del fluido: -40 a 177°C
Presión de operación máxima: 150psi
Precisión: ±0.75% lectura, ±0.5% full escala
Conexión al proceso: ¾”NPT-M ajustable con férula de teflón
Material de la conexión al proceso: acero inoxidable
Longitud de inserción: 1 a 6” (152,4mm)
Alimentación: 85 a 265 Vac (19.2 a 28.8 VDC)
Display de visualización y configuración.
Comunicación: Foundation Fieldbus H1
Compensación de temperatura extendida y VORTAB (VIP)
Protección: IP67
Aprobación: FM, FMc
S/ 0.00 0.0 PEN
TRANSMISOR DE FLUJO, -40 a 177°C, 150psi, ¾”NPT-M, 1 a 6” (152,4mm)
TRANSMISOR DE FLUJO
Marca: FCI
Aplicación: Aire
Montaje en tubería horizontal
Dirección del fluido: Izquierda a derecha o Vertical hacia arriba
Carcasa: Aluminio
Rango de temperatura del fluido: -40 a 177°C
Presión de operación máxima: 150psi
Precisión: ±0.75% lectura, ±0.5% full escala
Conexión al proceso: ¾”NPT-M ajustable con férula de teflón
Material de la conexión al proceso: acero inoxidable
Longitud de inserción: 1 a 6” (152,4mm)
Alimentación: 24 Vdc (19.2 a 28.8 VDC)
Comunicación: Foundation Fieldbus H1
Display de visualización y configuración.
Compensación de temperatura extendida y VORTAB (VIP)
Protección: IP67
Aprobación: FM, FMc
S/ 0.00 0.0 PEN
MULTI-JET WATER METER WITH PULSED OUTPUT, Max flow: 100 GMP
MULTI-JET WATER METER WITH PULSED OUTPUT
Brand: DWYER
Size: 1-1/2˝
Coupling size: 1-1/2˝ NPT
Max flow: 100 GMP
Nominal flow range: 5 to 100 
Transitional flow: 1.5
Display max: 99,999,999.9
Pulse rate: 10
S/ 0.00 0.0 PEN
MULTI-JET WATER METER WITH PULSED OUTPUT, Coupling Size: 1˝ NPT Max flow: 50
MULTI-JET WATER METER WITH PULSED OUTPUT
Brand: DWYER
Size: 1˝
Coupling Size: 1˝ NPT
Max flow: 50
Nominal flow range: 3 to 50
Transitional flow: 0.75
Display max: 99,999,999.9
Pulse Rate: 0.1
S/ 0.00 0.0 PEN
​MULTI-JET WATER METER WITH PULSED OUTPUT, Coupling Size: 3/4˝ NPT. Max flow: 30 GPM
MULTI-JET WATER METER WITH PULSED OUTPUT
Brand: DWYER
Size: 3/4
Coupling Size: 3/4˝ NPT.
Max flow: 30 GPM
Nominal flow range: 3 to 30
Transitional flow: 0.25
Display Max: 9,999,999,99
Pulse Rate: 0.1
S/ 1,950.08 1950.08 PEN
MIDWEST SIGHT FLOW INDICATORS, 1/2, Bronze
MIDWEST SIGHT FLOW INDICATORS
Brand: DWYER
Body Style: Single window, bronze body, ABS impeller
Body Size: 1/2 inch connection size
Service: Compatible gases and liquids.
Temperature Limit: 200°F (93°C)
Pressure Limit: 125 psig (8.62 bar)
Mounting Orientation: Horizontal or vertical; 360: Horizontal only.
S/ 0.00 0.0 PEN
FLUJOMETRO AREA VARIABLE, 20-190 LPM , 2 1/2”NPT, 6000 PSIG
BI-DIRECTIONAL VARIABLE AREA FLOW METER
Brand: LAKE MONITORS
[B]:Style: Basic online for liquids,
[5]: Port /Line Size Range: 1 1/4 "- 2"
[S]: Material: Stainless Steel
[7]: Range Max Pressure: 6000 PSIG
[W]: Middle fluid: water and 1.0 Specific Gravity
[M]: Thread type: 2 "NPTF
[50]: Flow Range: 20-190 LPM
[BI]: Bi-Directional Flow
Unrestricted Mounting
Allows for horizontal, vertical or inverted installation
and does not require straight plumbing on inlet or
outlet.
[Y]-Incluye adaptador de 2 a 2 ½” NPT.
S/ 7,107.75 7107.75 PEN
ULTRASONIC FLOWMETER, in (mm): 2 to 79 (50 to 2000)
ULTRASONIC FLOWMETER SETS
NON-INVASIVE PIPE FLOW MEASUREMENT, EASY OPERATION AND 
DATA LOGGING OPTION
Brand: DWYER(USA)
Pipe Size Range in (mm): 2 to 79 (50 to 2000)
Power Supply: 86 to 264 VAC
Service: Homogeneous liquids that do not contain more than 3% of air bubbles 
Or particulate and capable of ultrasonic wave propagation.
Inputs: TNC cable from sensors.
Range: 0.33 to 33 ft/s (0.1 to 10 m/s).
Display: 240 x 64 pixel graphic display, high contrast black on white with backlight;
Languages: English, French, German, Swedish, Italian, Spanish, Portuguese,
Russian, Norwegian, and Dutch; 5˝ W x 1.3˝ H (5 x 33.02 mm).
Accuracy: ±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and 
Pipe OD > 3.0 in (75 mm); 
±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and
pipe OD 0.5 to 3 in (13 to 75 mm)
±6% of flow reading for flow rate < 0.03 ft/s (0.01m/s).
Power Requirements: 86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max).
Power Consumption: 10.5 W.
Temperature Limits: Transducer: -4 to 275°F (-20 to 135°C)
Controller: -4 to 122°F (-20 to 50°C).
Outputs: Analog 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA
(selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 Ω max;
Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz;
Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width:
2 to 500 ms (selectable).
Serial Communications: USB (UFC only).
Enclosure Rating: IP65 when using TNC connector; Transducers IP54.
Materials: Plastic ABS and aluminum.
Repeatability: ±0.5 % of measured value or 0.03 ft/s (0.01 m/s).
Electrical Connections: Removable screw-in type terminal block.
Mounting: Wall mounted using 3 type M4 screws.
Turbidity: < 3 % by volume of particulate content.
Permissible Air Content: < 3% by volume.
Response Time: < 500 ms.
Weight: Unit not including accessories: 2.80 lb (1.26 kg); Unit including
accessories: 9.92 lb (4.5 kg).
Agency Approvals: CE.
ADDITIONAL SPECIFICATIONS
Applicable Pipe Material: Carbon steel, SS, copper, UPVC/PVDF, concrete, mild
steel, glass, brass.
Applicable Pipe Lining: Rubber, glass, concrete, epoxy, steel, other*.
Pipe Wall Thickness: 0.04 to 3˝ (1 to 75 mm).
Pipe Lining Thickness: < 1˝ (< 25 mm).
KIT INCLUDES
• Converter
• Set of transducers
• Ruled guide rail
• Steel banding
• Banding clips
• Set of transducer cables
• Set of high temperature interface cables
• Ultrasonic coupling grease
S/ 18,210.42 18210.420000000002 PEN
​DIRECT READING GLASS FLOWMETERS, 100 Air SCFH (50 L/min), 250°F (121°C)., 250 psig, 1/8" NPT
DIRECT READING GLASS FLOWMETERS
Brand: DWYER
Service: Compatible gases or liquids.
Max. Flow Rate: 100 Air SCFH (50 L/min)
Wetting Material: SS
Temperature Limit: 250°F (121°C).
Pressure Limit: 250 psig (17 bar).
Connection: 1/8˝ female NPT.
Repeatability: ±0.25% of scale reading.
Turn-Down Ratio: 10:1.
Mounting: Vertical.
S/ 0.00 0.0 PEN
GFM GAS MASS FLOW METER; 20LPM, N2
GFM GAS MASS FLOW METER
Brand: Dwyer
Repeatability: ±0.25% of full scale
Response Time: 2 seconds to within ±2% of actual flow
Output: Linear 0-5 VDC and 4-20 mA
Maximum Particulate Size: 5 microns
Temperature Limits:32 to 122°F (0 to 50°C)
Process Connections: 1/4" Compression Fitting
[21] Material: SST
[00] Range N° Range for Specialty Gas Only
[20] Range of Specialty Gas: 20 LPM
[N2] Specialty Gas K Factor and Desired Gas: 1.0000; NITROGEN
[24VDC] Options: 24 VDC
S/ 8,142.93 8142.93 PEN
CAUDALIMETRO DIGITAL , 2 NPT , 300 PSI , 30A 300GPM
CAUDALIMETRO DIGITAL 
Marca: GPI (USA)
Material : ALUMINIO 
Conexión : 2 NPT 
Presión máxima : 300 PSI 
Descripción :  30A 300GPM 
USO DE GASOLINA (MEZCLA DE ALCOHOL E15) COMBUSTIBLE DIESEL (MEZCLA DE BIODIESEL B20) KEROSENE







S/ 0.00 0.0 PEN
CAUDALIMETRO DIGITAL , 0.3 a 3GPM, -10ºC A +54ºC, 1” NPT
CAUDALIMETRO DIGITAL 
Marca : GPI (USA) 
Rango : 0.3 a 3GPM
Alimentación : 2 BATERIAS AAA
Material : ALUMINIO
Temperatura : -10ºC A +54ºC
Conexión : 1” NPT (HEMBRA)
Presión máxima : 300 PSI
Descripción : USO DE GASOLINA,COMBUSTIBLE DIESEL (MEZCLA DE BIODIESEL B20) KEROSENE
S/ 0.00 0.0 PEN
​MEDIDOR DE FLUJO TIPO TURBINA PARA LIQUIDOS, Max presión: 285 psi/220C
MEDIDOR DE FLUJO TIPO TURBINA PARA LIQUIDOS
Marca: AW FLOW METERS(USA) 
Versión completamente en acero inoxidable para alta duración y trabajo forzado 
Aplicación para medir aceites 
Rango de trabajo de 0.9 a 9 GPM 
Salida de Pulsos(MAG Hall Effect Pickup) 
Precisión:0.5% 
Conexión 1/2” NPT 
Max presión: 285 psi/220C 
S/ 0.00 0.0 PEN
FLOW RATE ALARMS, 1 switch, 1-1/4 - 2”, 600 psig, 1” NPTF
FLOW RATE ALARMS
BRAND: AW-LAKE
[M] METER STYLE, Flow Alarm (1 switch)
[5] PORT SIZE RANGE, 1-1/4 - 2”
[A] MATERIAL, Aluminum
[4] MAX. PRESSURE RATING, 600 psig (air & gas, aluminum & brass)
[H] FLUID MEDIA, Oil @ 0.873 specific gravity
[D] PORTING/THREAD TYPE, 1” NPTF, dry seal - 4 only
[10] FLOW RANGES, Liquid(1-10 GPM); Air(10-100 SCFM); Size(3 & 4)
S/ 0.00 0.0 PEN
SWITCH DE FLUJO CON INDICACION LOCAL , 4-20 MA,2"NPT,
SWITCH DE FLUJO CON INDICACION LOCAL
BRAND: UNIVERSAL FLOW MONITORS,
SETEO:34GPM FLUJO
MAX:60GPM,ESCALA DUAL GPM&LPM TRANSMISSOR 4-20 MA,2"NPT






S/ 0.00 0.0 PEN
SWITCH DE FLUJO CON INDICACION LOCAL , 4-20MA,3/4"NPT
SWITCH DE FLUJO CON INDICACION LOCAL
BRAND; UNIVERSAL FLOW MONITORS
SETEO:3GPM, FLUJO
MAX:6GPM,ESCALA DUAL GPM&LPM,TRANSMISSOR 4-20MA,3/4"NPT


S/ 0.00 0.0 PEN