SERVOTOUGH SpectraExact 2500F Analyser
SERVOTOUGH SpectraExact 2500F Analyser<br />
Marca: SERVOMEX<br />
Modelo: 02500F1<br />
Product SpectraExact 2500F Analyser<br />
Approval Type Safe Area<br />
Supply Voltage 115V 50-60Hz<br />
Phase of Sample Gaseous<br />
Measurement Carbon Monoxide<br />
Measurement Units 1 vpm<br />
Measurement Range 1 3,000.0<br />
Cell Heater and Temp Rating Electrically Heated <130C<br />
Cell Temperature (C) 130<br />
Cell Material Stainless Steel<br />
Cell Length 256mm Cell<br />
Sample Cell O Ring Material Viton<br />
Source Type CAF2 Long Wave Sealed<br />
Detector Type CaF2<br />
Lens Material CaF2<br />
Window Material CaF2<br />
Tag No 1445-AIT-0525<br />
Scrubbers H2O/CO2/CO Mix + Purged Bosses<br />
End Boss Purge Gas Nitrogen<br />
Relieving End Boses Not Required<br />
Sample Compensation Not Required<br />
Optional Outputs Not Required<br />
User Manual English<br />
Application Adder Application Adder - C<br />
Zero Calibration Component 100%N2<br />
Span Calibration Component 3000VPM CO BAL N2<br />
Calibration Temperature (C) 130<br />
Calibration Pressure (bara) 1.00<br />
Performance Specification As Published<br />
Stream Component 1 N2<br />
Stream Comp 1 Normal Range 16.6%<br />
Stream Comp 1 High Range 17.3%<br />
Stream Comp 1 Low Range 15.9%<br />
Stream Component 2 O2<br />
Stream Comp 2 Normal Range 48.5%<br />
Stream Comp 2 High Range 54.2%<br />
Stream Comp 2 Low Range 43.1%<br />
Stream Component 3 H2O<br />
Stream Comp 3 Normal Range 34.9%<br />
Stream Comp 3 High Range 39.5%<br />
Stream Comp 3 Low Range 29.9%<br />
Stream Component 4 CO2<br />
Stream Comp 4 Normal Range 1.0%<br />
Stream Comp 4 High Range 1.3%<br />
Stream Comp 4 Low Range 0.7%<br />
Stream Component 5 CO<br />
Stream Comp 5 Normal Range 1400PPM<br />
Stream Comp 5 High Range 2800PPM<br />
Stream Comp 5 Low Range 900PPM<br /><br />
1. Gases de Calibración:<br />
Gas cero: 100% N2<br />
Gas patrón: 3000 vpm CO Bal N2<br />
2. Se requiere una muestra sin condensación en la entrada<br />
3. Presión de ventilación de muestra atmosférica constante.<br />
4. El analizador se ubicará donde el rango de temperatura ambiente sea de 0 a 55 °C.<br />
5. Debido al O2 enriquecido en la muestra, el cliente debe asegurarse de que el nivel de CO sea lo suficientemente bajo para<br />
evitar que ocurran condiciones explosivas.<br />
6. El protocolo HART no está disponible en la serie 2500<br />
7. Se requiere tubería de trazado de calor para la línea de muestra.
Marca: SERVOMEX |
Línea: SERVOMEX (CM) |