GASMAX II Gas Monitor - Detector ( 0 -100 % LEL PROPANE)
<div><strong>Modelo:<span> </span>GMII-0-00-0-2-51-6-0-0</strong></div>
<div></div>
<div>•<span> </span>GASMAX II Gas Monitor Single / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations</div>
<div>•<span> </span>Power Input:<span> </span>10-30VDC at < 4 watts with relay board. Additional power required for Extended Temp & GDS-IR option.</div>
<div>•<span> </span>Display:<span> </span>Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph </div>
<div>•<span> </span>Electrochemical Sensor Input:<span> </span>Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors or 4-20mA current source</div>
<div>•<span> </span>Bridge Type Sensor Input:<span> </span>Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead or 4-20mA current source</div>
<div>•<span> </span>Standard Output:<span> </span>Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply</div>
<div>•<span> </span>Optional Outputs:<span> </span>Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC; Single or dual MODBUS slave ports; 3x program-mable alarm relays with 5A capability </div>
<div>•<span> </span>Temp:<span> </span>Electronics -40°C to +60°C; See Echem Sensor Manual for sensor limits</div>
<div>•<span> </span>Housing :<span> </span>Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)</div>
<div>•<span> </span>Dimensions:<span> </span>Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)</div>
<div>•<span> </span>Approvals:<span> </span>CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP installations</div>
<div>•<span> </span>Warranty:<span> </span>2 years on electronics and one year on sensors<br />
</div>
<div></div>
<div>//////////<strong>CODIGOS PARA ORDENAR</strong>///////</div>
<div></div>
<div>•<span> </span>GMII: <span> </span>GASMAX II Gas MonitorSingle / Dual Channel Toxic & Combustible Gas Monitor for Hazardous Locations</div>
<div></div>
<div><br /><strong>o<span> </span>Chanel 1</strong></div>
<div>•<span> </span>0:<span> </span>Sensor Head (No sensor head)</div>
<div>•<span> </span>00:<span> </span>Senor Type (No sensor)</div>
<div>•<span> </span>0: Target Gas Range (None)</div>
<div></div>
<div><br /><strong>o<span> </span>Chanel 2</strong></div>
<div>•<span> </span>2:<span> </span>Sensor Head (Local sensor head with splash guard)</div>
<div>•<span> </span>51:<span> </span>Senor Type (SmartIR 0 to 100% LEL Propane)</div>
<div>•<span> </span>6: Target Gas Range (0 - 100% LEL)</div>
<div></div>
<div><br /><strong>o<span> </span>Output</strong></div>
<div>•<span> </span>0:<span> </span>standard 4 -20 ma output (3-wires)</div>
<div>•<span> </span>0:<span> </span>standard temperature range</div>
Brand: GDS |